ORCHARD PARK, NY —
OSHA Inspection: P M PLASTICS, INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of P M PLASTICS, INC. in 1 BANK STREET, ORCHARD PARK, NY 14127 (NAICS 326199). OSHA activity number 347699720.
Where did this inspection happen?
- Establishment
- P M PLASTICS, INC.
- Site address
- 1 BANK STREET
- City
- ORCHARD PARK
- State
- NY
- ZIP
- 14127
- Mailing
- 1 BANK STREET, ORCHARD PARK, NY 14127
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 326199
- Employees
- 36
- Ownership type
- A
Citations
3 citations on file for this inspection.
1910.147 C04 I
- Issued
- Abate by
- Penalty
- Initial $6857.00 · Current $4500.00 Reduced
General-duty citation text
29 CFR 1910.147(c)(4)(i): Procedures were not developed and documented for the control of potentially hazardous energy when employees were engaged in activities covered by this section: a) On or about 08/20/2024 in the production areas; where there are approximately 22 injection molding machines which have multiple sources of energy. The employer did not have documented specific energy control procedures for those machines. ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
- — I (S) $4500
- — Z (S) $6857
1910.303 F01
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.303(f)(1):Each disconnecting means required by Subpart S of Part 1910 for motors and appliances was not legibly marked to indicate its purpose, nor located and arranged so the purpose was evident: a) On or about 08/20/2024 in the production department; where the electrical disconnect for machine #7 was marked as #9. ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.304 G06 VI
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.304(g)(6)(vi):Exposed noncurrent-carrying metal parts of cord- and plug-connected equipment that could have become energized were not grounded: a) On or about 08/200/2024 in the production area; where portable fans with non-current carrying metal parts were used for comfort ventilation, either the fan was not grounded or the grounding pin was missing from the plug end. ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections in this industry (NAICS 326199)
CONNEAUT, OH—2026-07-13
CONTINENTAL STRUCTURAL PLASTICS
PETALUMA, CA—2026-07-10
LABCON NORTH AMERICA
KEEWATIN, MN—2026-07-09
111565 - TACKLE TAMER PRODUCTS INC
EAST FLAT ROCK, NC—2026-07-09
161517 - ELKAMET, INC.
LANESBOROUGH, MA—2026-07-08
LANSEN MOLD CO., INC.
More inspections in NY
POUGHKEEPSIE, NY—2026-07-13
MARCO BOARD HOUSE, INC.
CORTLANDT MANOR, NY—2026-07-13
LG BUILDERS INC.
CORTLANDT MANOR, NY—2026-07-13
RJW RENOVATIONS, LLC
HEMPSTEAD, NY—2026-07-13
NYSDOCCS NASSAU AREA OFFICE
NIAGARA FALLS, NY—2026-07-10
NTVI FEDERAL INC
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 347699720.