Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,214Inspections Most recent open 2026-07-16 Last loaded 2026-07-20

OSHA Inspection: YELLOWSTONE BLAST SERVICES, LLC

Complaint inspection · Health discipline

On , OSHA opened a complaint health inspection of YELLOWSTONE BLAST SERVICES, LLC in 13630 50TH WAY NORTH, CLEARWATER, FL 33760 (NAICS 332813). OSHA activity number 347711376.

Watch Yellowstone Blast Services, LLC — free Get an email when a new federal OSHA severe-injury report for Yellowstone Blast Services, LLC is published. One employer, no account, unsubscribe in one click.
Site address
13630 50TH WAY NORTH
City
CLEARWATER
State
FL
ZIP
33760
Mailing
13630 50TH WAY NORTH, CLEARWATER, FL 33760
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332813
Employees
5
Ownership type
A

5 citations on file for this inspection.

1910.107 B05 I

Deleted Other-than-serious 2 instances 3 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00

Hazardous substances 1080249025909130

29 CFR  1910.107(b)(5)(i): There were no visible gauges, audible alarms or pressure activated devices installed in paint spray booths to indicate or ensure that the required air speed was maintained.  a) In the blast booth, on or about August 26, 2024, the employer did not have a visible gauge to ensure that the air velocity in the booth was maintained. b) In the paint booth, on or about August 26, 2024, the employer did not have a visible gauge to ensure that the air velocity in the booth was maintained.
Recent events (3)
  • — F (O) $0
  • — C (O) $0
  • — Z (O) $0

1910.134 D01 II

Deleted Other-than-serious 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00

Hazardous substances 9130

29 CFR 1910.134(d)(1)(ii): The employer did not select and use a NIOSH-certified respirator in compliance with the conditions of its certification:  a) In the blast booth, on or about August 26, 2024, employees used a Clemco Respirator Air Supply Hose 04465-00 EB 3/8"xif 250 WP 3/8" (9.5 mm) 250 PSI W.P air hose that was not certified for use with the Nova 3 Blasting Helmets.
Recent events (3)
  • — F (O) $0
  • — C (O) $0
  • — Z (O) $0

1910.134 E01

Other-than-serious 1 instance 2 exposed
Issued
Penalty
Initial $0.00 · Current $0.00

Hazardous substances 108024902590

29 CFR  1910.134(e)(1): The employer did not provide a medical evaluation to determine the employee's ability to use a respirator, before the employee was fit tested or required to use the respirator in the workplace:   a) In the paint booth, on or about August 26, 2024, the employer did not provide a medical evaluation which covered employees that were required to wear 3M full face respirator, 3M half face respirator, and/or 3M N95 tight fitting 8210V respirators.
Recent events (3)
  • — F (O) $0
  • — C (O) $0
  • — Z (O) $0

1910.134 F02

Other-than-serious 1 instance 2 exposed
Issued
Penalty
Initial $0.00 · Current $0.00

Hazardous substances 108024902590

29 CFR  1910.134(f)(2): Employee(s) using tight-fitting facepiece respirators were not fit tested prior to initial use of the respirator:   a) In the paint booth, on or about August 26, 2024, the employer did not provide fit testing which covered employees that were required to wear 3M full face respirator, 3M half face respirator, and/or 3M N95 tight fitting 8210V respirators.
Recent events (3)
  • — F (O) $0
  • — C (O) $0
  • — Z (O) $0

1910.134 G01 I A

Deleted Other-than-serious 3 instances 2 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00

Hazardous substances 108024902590

29 CFR  1910.134(g)(1)(i)(A): Respirators with tight-fitting facepieces were worn by employees who had facial hair that came between the sealing surface of the facepiece and the face or that interfered with valve function:   a) In the paint booth, on or about August 26, 2024, employees used a 3M full face respirator while having facial hair that came between the sealing surface of the facepiece and the face. b) In the paint booth, on or about August 26, 2024, employees used a 3M half face respirator while having facial hair that came between the sealing surface of the facepiece and the face. c) In the paint booth, on or about August 26, 2024, employees used a 3M N95 tight fitting 8210V respirators while having facial hair that came between the sealing surface of the facepiece and the face.
Recent events (3)
  • — F (O) $0
  • — C (O) $0
  • — Z (O) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 347711376.