1,224,460Inspections Most recent open 2026-07-13 Last loaded 2026-07-16
Safety Incidents OSHA Severe Injury Reports · 2015–2025

OSHA Inspection: JOY GLOBAL UNDERGROUND MINING LLC

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of JOY GLOBAL UNDERGROUND MINING LLC in 6160 COCHRAN RD, SOLON, OH 44139 (NAICS 333131). OSHA activity number 347735755.

Watch JOY Global Underground Mining LLC — free Get an email when a new federal OSHA severe-injury report for JOY Global Underground Mining LLC is published. One employer, no account, unsubscribe in one click.
Site address
6160 COCHRAN RD
City
SOLON
State
OH
ZIP
44139
Mailing
6160 COCHRAN RD, SOLON, OH 44139
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
A
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
333131
Employees
1650
Ownership type
A

2 citations on file for this inspection.

1910.147 C04 II B

Other-than-serious Gravity 5 1 instance 4 exposed
Issued
Abate by
Penalty
Initial $8296.00 · Current $8296.00
29 CFR 1910.147(c)(4)(ii)(B): Specific procedural steps for shutting down, isolating, blocking and securing machines or equipment to control hazardous energy;   On or about August 22, 2024, the employer?s hazardous energy control procedure for the No. 5 Heat Treat Furnace did not include procedural steps for isolating the hazardous energy sources for the agitator.
Recent events (3)
  • — F (O) $8296
  • — C (S) $8296
  • — Z (S) $8296

1910.147 D

Deleted Serious Gravity 5 1 instance 4 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR  1910.147(d):Application of control. The established procedures for the application of energy control (the lockout or tagout procedures) shall cover the following elements and actions and shall be done in the following sequence:  On or before May 28, 2024, the employer did not ensure maintenance repair employees engaged in the service and maintenance of the No.5 Heat Treat Furnace applied and followed the established energy control procedure by; isolating the electrical, gas, chemical, pneumatic and gravitational energy sources [per 1910.147(d)(3)], affixing lockout devices [per 1910.147(d)(4)(i)], or verifying de-energization and isolation had been accomplished [per 1910.147(d)(6)], prior to removing the right-side agitator from the furnace.
Recent events (3)
  • — F (S) $0
  • — C (S) $0
  • — Z (S) $0