WINDSOR, CT —
OSHA Inspection: FOGARTY'S HOME SERVICES LLC
Complaint inspection · Health discipline
At a glance
On , OSHA opened a complaint health inspection of FOGARTY'S HOME SERVICES LLC in 800 PROSPECT HILL RD, WINDSOR, CT 06095 (NAICS 238310). OSHA activity number 347737496.
Where did this inspection happen?
- Establishment
- FOGARTY'S HOME SERVICES LLC
- Site address
- 800 PROSPECT HILL RD
- City
- WINDSOR
- State
- CT
- ZIP
- 06095
- Mailing
- 800 PROSPECT HILL RD, WINDSOR, CT 06095
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238310
- Employees
- 26
- Ownership type
- A
Citations
5 citations on file for this inspection.
1910.134 E01
- Issued
- Abate by
- Penalty
- Initial $9680.00 · Current $4840.00 Reduced
General-duty citation text
29 CFR 1910.134(e)(1):The employer did not provide a medical evaluation to determine the employee's ability to use a respirator, before the employee was fit tested or required to use the respirator in the workplace: (a) Fogarty's Home Services dba Dr Energy Saver, 800 Prospect Hill Rd, Windsor, CT 06095; On or about September 6, 2024, and at times prior, employees were exposed to potential negative health effects from wearing a half-face tight-fitting respirator when the employer did not ensure that all employees who were required to wear respirators while conducting normal job operations were medically evaluated prior to use of the respirator.
Recent events (2)
- — I (S) $4840
- — Z (S) $9680
1910.134 F02
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.134(f)(2):Employee(s) using tight-fitting facepiece respirators were not fit tested prior to initial use of the respirator: (a) Fogarty's Home Services dba Dr Energy Saver, 800 Prospect Hill Rd, Windsor, CT 06095; On or about September 6, 2024, and at times prior, the employer did not ensure that all employees who were required to wear a tight-fitting respirator while conducting normal job operations, such as spraying HandiFoam Low Density Polyurethan Spray Foam, were given a fit test prior to initial use of the respirator.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.134 G01 I A
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.134(g)(1)(i)(A):Respirators with tight-fitting facepieces were worn by employees who had facial hair that came between the sealing surface of the facepiece and the face or that interfered with valve function: (a) Fogarty's Home Services dba Dr Energy Saver, 800 Prospect Hill Rd, Windsor, CT 06095; On or about September 6, 2024, and at times prior, employees were exposed to potential chemical hazards while wearing a mandatory half-face respirator with facial hair that interfered with the seal. Employees wear respirators with long facial hair while spraying polyurethane foam cleaner.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.132 D02
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.132(d)(2):The employer did not verify, through a written certification, the identity of the workplace evaluated, the person certifying that the evaluation had been performed, and the date the hazard assessment was done: (a) Fogarty's Home Services dba Dr Energy Saver, 800 Prospect Hill Rd, Windsor, CT 06095; On or about September 6, 2024, and at times prior, the employer did not perform a hazard assessment to determine appropriate personal protective equipment required to protect employees from hazards while spraying polyurethane foam cleaner.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1904.40 A
- Issued
- Abate by
- Penalty
- Initial $1000.00 · Current $500.00 Reduced
General-duty citation text
29 CFR 1904.40(a):The employer did not provide an authorized government representative the records within the four business hours. (a) Fogarty's Home Services dba Dr Energy Saver, 800 Prospect Hill Rd, Windsor, CT 06095; On or about September 6, 2024, and at times prior, the employer failed to provide copies of the injury and illness records to an authorized representative within 4 hours of request. An employer may use the business hours of the establishment at which the records are located when calculating the deadline.
Recent events (2)
- — I (O) $500
- — Z (O) $1000
More inspections in this industry (NAICS 238310)
ELLETTSVILLE, IN—2026-07-13
ENVIRO HEAT, LLC
ELLETTSVILLE, IN—2026-07-13
RWS INSULATION SERVICES, LLC
IRVINE, CA—2026-07-10
COAST BUILDING PRODUCTS
FRANCESTOWN, NH—2026-07-10
D&D INSULATION, LLC
DOWNINGTOWN, PA—2026-07-09
CAPITAL INTERIOR, LLC
More inspections in CT
BRIDGEPORT, CT—2026-07-10
WRR, INC.
BERLIN, CT—2026-07-10
MMF CONSTRUCTION LLC
NAUGATUCK, CT—2026-07-08
WHITING-TURNER LCT2 JOINT VENTURE
SOMERS, CT—2026-07-08
F&G RECYCLING LLC
STAMFORD, CT—2026-07-07
FAIRFIELD AVENUE MAINTENANCE COMPANY, INC.
Source