TONAWANDA, NY —
OSHA Inspection: PILATAXI CONSTRUCTION
Unprogrammed Other inspection · Safety discipline
At a glance
On , OSHA opened an unprogrammed Other safety inspection of PILATAXI CONSTRUCTION in 147 HENDERSON ST, TONAWANDA, NY 14150 (NAICS 238160). OSHA activity number 347757882.
Where did this inspection happen?
- Establishment
- PILATAXI CONSTRUCTION
- Site address
- 147 HENDERSON ST
- City
- TONAWANDA
- State
- NY
- ZIP
- 14150
- Mailing
- 251 PARKHURST BLVD, BUFFALO, NY 14223
What kind of inspection was it?
- Inspection type
- Unprogrammed Other (I)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238160
- Employees
- 5
- Ownership type
- A
Citations
2 citations on file for this inspection.
1926.501 B11
- Issued
- Penalty
- Initial $2498.00 · Current $1650.00 Reduced
General-duty citation text
29 CFR 1926.501(b)(11): Each employee on a steep roof with unprotected sides and edges 6 feet (1.8 m) or more above lower levels was not protected from falling by guardrail systems with toeboards, safety net systems, or personal fall arrest systems: a) On or about 09/12/2024, at a residential roof project located at 147 Henderson St in Tonawanda, NY; employees were installing shingles on the roof of a two-story home. The roof had a 5 in 12 pitch with an eave height of approximately 20 feet. There was no fall protection in use. NO ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
- — I (S) $1650
- — Z (S) $2498
1926.1053 B01
- Issued
- Penalty
- Initial $1998.00 · Current $1100.00 Reduced
General-duty citation text
29 CFR 1926.1053(b)(1): Where portable ladders were used for access to an upper landing surface and the ladder's length allows, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface being accessed. a) On or about 09/12/2024 at the roof area of the site, side rails of the extension ladder did not extend 3 feet above the upper landing surface being accessed. Employees were exposed to falls. NO ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
- — I (S) $1100
- — Z (S) $1998
More inspections in this industry (NAICS 238160)
SIOUX FALLS, SD—2026-07-13
H & R ROOFING OF SOUTH DAKOTA, INC.
HENDERSON, NV—2026-07-13
INTEGRITY ROOFING LLC
CORTLANDT MANOR, NY—2026-07-13
LG BUILDERS INC.
CAMDEN, OH—2026-07-13
ALBERTO MORALES
BLOOMINGTON, IL—2026-07-13
UNKNOWN CONTRACTOR
More inspections in NY
POUGHKEEPSIE, NY—2026-07-13
MARCO BOARD HOUSE, INC.
CORTLANDT MANOR, NY—2026-07-13
LG BUILDERS INC.
CORTLANDT MANOR, NY—2026-07-13
RJW RENOVATIONS, LLC
HEMPSTEAD, NY—2026-07-13
NYSDOCCS NASSAU AREA OFFICE
NIAGARA FALLS, NY—2026-07-10
NTVI FEDERAL INC
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 347757882.