Safety Incidents OSHA Severe Injury Reports · 2015–2025
4,113,118Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: JORGE'S PROFESSIONAL ROOFING LLC

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of JORGE'S PROFESSIONAL ROOFING LLC in 107 WILLIAMS DR., RICHMOND HILL, GA 31324 (NAICS 238160). OSHA activity number 347763039.

Watch Jorge'S Professional Roofing LLC — free Get an email when a new federal OSHA severe-injury report for Jorge'S Professional Roofing LLC is published. One employer, no account, unsubscribe in one click.
Site address
107 WILLIAMS DR.
City
RICHMOND HILL
State
GA
ZIP
31324
Mailing
231 QUACCO RD. LOT 26, SAVANNAH, GA 31419
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238160
Employees
6
Ownership type
A

4 citations on file for this inspection.

1926.501 B13

Serious Gravity 10 1 instance 4 exposed
Issued
Penalty
Initial $4839.00 · Current $4839.00
29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b).   a.) Roof: On or about September 18, 2024, the employer exposed employees to a fall hazard, in that employees were not required to use fall protection while installing roofing on a residential home with an 11' eaves to ground fall distance.
Recent events (1)
  • — Z (S) $4839

1926.502 D15

Serious Gravity 10 1 instance 2 exposed
Issued
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.502(d)(15): Anchorage used for attachment for personal fall arrest equipment was not capable of supporting at least 5,000 pounds (22.2 kN) per employee attached nor was it designed, installed and used as follows: As part of a complete personal fall arrest system which maintains a safety factor of at least two; and under the supervision of a qualified person.  a) Roof: On or about September 18, 2024, the employer exposed employees to fall hazards, in that the anchorage being utilized for attachment of personal fall arrest equipment by two employees was not capable of supporting at least 5,000 pounds per employee attached.
Recent events (1)
  • — Z (S) $0

1926.502 D17

Serious Gravity 10 1 instance 2 exposed
Issued
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.502(d)(17): The attachment point of the body harness was not located in the center of the wearer's back near shoulder level, or above the wearer's head.  a) Roof: On or about September 18, 2024, the employer exposed employees to fall hazards, in that employees utilizing fall arrest equipment did not have their attachment points in the center of their backs near shoulder level, instead having their attachment point at the front of the waist.
Recent events (1)
  • — Z (S) $0

1926.1053 B01

Serious Gravity 5 1 instance 6 exposed
Issued
Penalty
Initial $2765.00 · Current $2765.00
29 CFR 1926.1053(b)(1): Where portable ladders were used for access to an upper landing surface and the ladder's length allows, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface being accessed.  a.) Front of the house: On or about September 18, 2024, the employer exposed employees to fall hazards, in that the extension ladder used for access to the roof did not extend at least 3 feet above the edge of the roof.
Recent events (1)
  • — Z (S) $2765

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 347763039.