BIG SPRING, TX —
OSHA Inspection: FOSS ENERGY SERVICES, INC.
Federal Agency inspection · Safety discipline
At a glance
On , OSHA opened a federal Agency safety inspection of FOSS ENERGY SERVICES, INC. in 32.23.16.3, -101.42.12.7W, BIG SPRING, TX 79720 (NAICS 237120). OSHA activity number 347782039.
Where did this inspection happen?
- Establishment
- FOSS ENERGY SERVICES, INC.
- Site address
- 32.23.16.3, -101.42.12.7W
- City
- BIG SPRING
- State
- TX
- ZIP
- 79720
- Mailing
- 2305 RIDGE RD., STE 202, ROCKWALL, TX 75087
What kind of inspection was it?
- Inspection type
- Federal Agency (M)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Last modified
- Data loaded
Establishment context
- NAICS code
- 237120
- Employees
- 6
- Ownership type
- A
Citations
6 citations on file for this inspection.
1910.252 A02 IV
- Issued
- Abate by
- Penalty
- Initial $14895.00 · Current $14895.00
General-duty citation text
29 CFR 1910.252(a)(2)(iv): The individual responsible for authorizing cutting or welding operations did not designate precautions to be followed in granting authorization to proceed preferably in the form of a written permit. On or about September 26, 2024, at the tank battery, the employer did not designate precautions prior to allowing welding operations on or near produced water tanks.
Recent events (2)
- — C (S) $14895
- — Z (S) $14895
1910.252 A02 III A
- Issued
- Abate by
- Penalty
- Initial $14895.00 · Current $14895.00
General-duty citation text
29 CFR 1910.252(a)(2)(iii)(A): The employer did not provide fire watchers whenever welding or cutting was performed in locations where other than a minor fire might develop On or about September 26, 2024, at the tank battery, the employer did not designate a fire watcher prior to allowing welding operations on or near produced water.
Recent events (2)
- — C (S) $14895
- — Z (S) $14895
1910.252 A02 VI C
- Issued
- Abate by
- Penalty
- Initial $14895.00 · Current $14895.00
General-duty citation text
29 CFR 1910.252(a)(2)(vi)(C): Cutting or welding was permitted in the presence of explosive atmospheres (mixture of flammable gases, vapors, liquids, or dusts with air), or explosive atmospheres that could develop inside uncleaned or improperly prepared tanks or equipment which had previously contained such materials, or that could develop in areas with an accumulation of flammable gases. On or about September 26, 2024, at the tank battery, where the employer allowed welding in the presence of explosive atmosphere.
Recent events (2)
- — C (S) $14895
- — Z (S) $14895
1910.252 A02 XIV B
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.252(a)(2)(xiv)(B): The employer did not ensure that the supervisor determined the combustible materials and hazardous areas present or likely to be present in the work location On or about September 26, 2024, at the tank battery, the employer did not designate precautions to be followed prior to allowing welding operations on or near produced water tanks.
Recent events (2)
- — C (S) $0
- — Z (S) $0
1910.252 A03 I
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.252(a)(3)(i): Welding, cutting, or other hot work was performed on used drums, barrels, tanks, or other containers that had not been cleaned so thoroughly as to make absolutely certain there were no flammable materials present or any substances such as greases, tars, acids, or other materials which where subjected to heat, might produce flammable or toxic vapors On or about September 26, 2024, at the tank battery, the employer did not ensure that tanks containing produced water were empty and free of flammable materials or substances, prior to welding operations on or near produced water tanks.
Recent events (2)
- — C (S) $0
- — Z (S) $0
1910.252 A03 II
- Issued
- Abate by
- Penalty
- Initial $14895.00 · Current $14895.00
General-duty citation text
29 CFR 1910.252(a)(3)(ii): All hollow spaces, cavities, or containers were not vented to permit the escape of air or gases before preheating, cutting, or welding was performed On or about September 26, 2024, at the tank battery, the employer did not not vent out piping prior to allowing welding operations on or near produced water.
Recent events (2)
- — C (S) $14895
- — Z (S) $14895
More inspections in this industry (NAICS 237120)
ODEM, TX—2026-07-09
MPG PIPELINE CONTRACTORS, LLC
FREMONT, MI—2026-07-07
ROESE PIPELINE COMPANY, INC.
BROOK PARK, OH—2026-06-30
MICHELS FOUNDATIONS - FRANKSVILLE, A DIVISION OF MICHELS CONSTRUCTION, INC.
HAZLE TOWNSHIP, PA—2026-06-24
LINDE CORPORATION
MONAHANS, TX—2026-06-12
TROY CONSTRUCTION, LLC
More inspections in TX
SPRING, TX—2026-07-10
DORSTENER WIRE TECH INC.
FORT WORTH, TX—2026-07-10
RC PROFESSIONAL ROOFING OF TEXAS LLC
CYPRESS, TX—2026-07-10
FEDERICO CARVAJAL GARCIA
SAN ANTONIO, TX—2026-07-10
ED LONG'S METAL WORKS
SAN ANTONIO, TX—2026-07-09
WAREHOUSE RACK COMPANY, LP
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 347782039.