Safety Incidents OSHA Severe Injury Reports · 2015–2025
4,113,118Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: 76423 - FLEXTRONICS INTERNATIONAL USA INC

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of 76423 - FLEXTRONICS INTERNATIONAL USA INC in 1000 TECHNOLOGY DRIVE, WEST COLUMBIA, SC 29170 (NAICS 334412). OSHA activity number 347784431.

Watch 76423 - Flextronics International USA INC — free Get an email when a new federal OSHA severe-injury report for 76423 - Flextronics International USA INC is published. One employer, no account, unsubscribe in one click.
Site address
1000 TECHNOLOGY DRIVE
City
WEST COLUMBIA
State
SC
ZIP
29170
Mailing
1000 TECHNOLOGY DRIVE, WEST COLUMBIA, SC 29170
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
334412
SIC code (legacy)
3672
Employees
800
Ownership type
A

1 citation on file for this inspection.

1910.147 C04 I

Other-than-serious 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $1875.00 · Current $1500.00 Reduced
Recent events (2)
  • — I (O) $1500
  • — Z (S) $1875