Safety Incidents OSHA Severe Injury Reports · 2015–2025
2,004,209Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: SUNOCO LP NLR

Unprogrammed Related inspection · Safety discipline

On , OSHA opened an unprogrammed Related safety inspection of SUNOCO LP NLR in 2207 CENTRAL AIRPORT ROAD, NORTH LITTLE ROCK, AR 72117 (NAICS 424710). OSHA activity number 347792350.

Watch Sunoco LP NLR — free Get an email when a new federal OSHA severe-injury report for Sunoco LP NLR is published. One employer, no account, unsubscribe in one click.
Establishment
SUNOCO LP NLR
Site address
2207 CENTRAL AIRPORT ROAD
City
NORTH LITTLE ROCK
State
AR
ZIP
72117
Mailing
2207 CENTRAL AIRPORT ROAD, NORTH LITTLE ROCK, AR 72117
Inspection type
Unprogrammed Related (G)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
424710
Employees
7
Ownership type
A

3 citations on file for this inspection.

1910.303 B02

Other-than-serious Gravity 1 1 instance 7 exposed
Issued
Penalty
Initial $6384.00 · Current $6384.00
29 CFR  1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling:  On or about October 2, 2024, by the front entrance to the office, employees were performing office work where an indoor extension cord was used outdoors to power a light.
Recent events (2)
  • — I (O) $6384
  • — Z (S) $6384

1910.305 G01 IV A

Other-than-serious Gravity 1 1 instance 7 exposed
Issued
Penalty
Initial $6384.00 · Current $6384.00
29 CFR  1910.305(g)(1)(iv)(A): Flexible cords and/or cables were used as a substitute for the fixed wiring of a structure:  On or about October 2, 2024, by the front entrance to the office, employees were performing office work where two extension cords were used instead of permanent wiring.
Recent events (2)
  • — I (O) $6384
  • — Z (S) $6384

1910.305 G01 IV B

Other-than-serious Gravity 1 1 instance 7 exposed
Issued
Penalty
Initial $6384.00 · Current $6384.00
29 CFR  1910.305(g)(1)(iv)(B): Flexible cords and/or cables were run through holes in walls, ceilings, or floors:  On or about October 2, 2024, by the front entrance to the office, employees were performing office work where an orange extension cord was run through a hole in the ceiling.
Recent events (2)
  • — I (O) $6384
  • — Z (S) $6384