OLEAN, NY —
OSHA Inspection: MAZZA MECHANICAL SERVICES
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of MAZZA MECHANICAL SERVICES in 430 NORTH 7TH STREET, OLEAN, NY 14760 (NAICS 333415). OSHA activity number 347793200.
Where did this inspection happen?
- Establishment
- MAZZA MECHANICAL SERVICES
- Site address
- 430 NORTH 7TH STREET
- City
- OLEAN
- State
- NY
- ZIP
- 14760
- Mailing
- 430 NORTH 7TH STREET, OLEAN, NY 14760
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 333415
- Employees
- 15
- Ownership type
- A
Citations
3 citations on file for this inspection.
1910.147 C06 I
- Issued
- Abate by
- Penalty
- Initial $7052.00 · Current $4000.00 Reduced
General-duty citation text
29 CFR 1910.147(c)(6)(i): The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed: a) On or about 10/03/2024, throughout the establishment; employer did not conduct periodic inspections of the Lockout/Tagout procedures at least annually to verify each procedure was adequate and being properly used by employees responsible for locking out machines during servicing or maintenance, such as but not limited to; Hydraulic Bender Roto-Die Press Brake Model 15 Serial #98845, DeWalt DW756 Bench Grinder, and Koike Aronson Plasma cutting table Model DM510 Serial #95084. ABATEMENT DOCUMENTATION REQUIRED
Recent events (2)
- — I (S) $4000
- — Z (S) $7052
1910.212 A01
- Issued
- Abate by
- Penalty
- Initial $8816.00 · Current $6000.00 Reduced
General-duty citation text
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks: a) On or about 10/03/2024, in the Press Brake Area; Employees were exposed to amputation hazards when Hydraulic Bender Roto-Die Press Brake Model 15 Serial #98845 point of operation was not guarded. Metal bending operations were performed when the EZ-Screen Banner light curtains were improperly installed above the point of operation such that the light curtain did not guard the point of operation. ABATEMENT DOCUMENTATION REQUIRED
Recent events (2)
- — I (S) $6000
- — Z (S) $8816
1910.215 B09
- Issued
- Penalty
- Initial $3966.00 · Current $2000.00 Reduced
General-duty citation text
29 CFR 1910.215(b)(9):The distance between the abrasive wheel periphery(s) and the adjustable tongue or the end of the safety guard peripheral member at the top exceeded one fourth inch: a) On or about 10/03/2024, throughout the establishment; employees were exposed to being struck by flying debris when using the DeWalt DW756 Bench Grinder to sharpen tungsten for tig welding with a tongue guard adjusted to more than 1/4 inch. NO ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
- — I (S) $2000
- — Z (S) $3966
More inspections in this industry (NAICS 333415)
LAUREL, MS—2026-07-01
THERMO-KOOL
OSSEO, WI—2026-07-01
TITAN AIR, LLLP
OSSEO, WI—2026-06-22
TITAN AIR, LLLP
LA CROSSE, WI—2026-05-28
TRANE U.S. INC.
COLONIAL HEIGHTS, VA—2026-05-26
HILL PHOENIX, INC.
More inspections in NY
MAYVILLE, NY—2026-07-16
MAYVILLE VILLAGE DPW
NEW HYDE PARK, NY—2026-07-16
NORTH HEMPSTEAD TN MICHAEL J TULLY PARK
CONESUS, NY—2026-07-16
CONESUS TN HIGHWAY DEPT
COMSTOCK, NY—2026-07-15
NYSDOCCS WASHINGTON CORRECTIONAL FACILITY
BALDWINSVILLE, NY—2026-07-15
LYSANDER TOWN HIGHWAY DEPARTMENT
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 347793200.