MUSTANG, OK —
OSHA Inspection: JOHN TORRES
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of JOHN TORRES in 10420 SW 49TH ST, MUSTANG, OK 73064 (NAICS 238130). OSHA activity number 347825333.
Where did this inspection happen?
- Establishment
- JOHN TORRES
- Site address
- 10420 SW 49TH ST
- City
- MUSTANG
- State
- OK
- ZIP
- 73064
- Mailing
- 633 SW 14TH ST, MOORE, OK 73160
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238130
- Employees
- 4
- Ownership type
- A
Citations
3 citations on file for this inspection.
1926.451 B02
- Issued
- Penalty
- Initial $3618.00 · Current $2100.00 Reduced
General-duty citation text
29 CFR 1926.451(b)(2):Scaffold platforms and walkways were not at least 18 inches wide. On or about October 18, 2024, on a scaffold erected on the second level of the residential building; an employee was performing framing work activities from a scaffold that was not at least eighteen (18) inches in width.
Recent events (2)
- — I (S) $2100
- — Z (S) $3618
1926.451 G01
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1926.451(g)(1): Employees on scaffolds more than 10 feet (3.1 m) above a lower level were not protected from falling to that lower level by fall protection established in paragraphs (g)(1)(i)-(vii) of this section. On or about October 18, 2024, on a scaffold erected on the second level of the residential building; an employee was not in use of fall protection while performing framing work activities from a scaffold that was more than ten(10) feet in height to the ground below.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.501 B01
- Issued
- Abate by
- Penalty
- Initial $2837.00 · Current $0.00 Reduced
General-duty citation text
29 CFR 1926.501(b)(1): Each employee on a walking/working surface with an unprotected side or edge which was 6 feet (1.8 m) or more above a lower level was not protected from falling by the use of guardrail systems, safety net systems, or personal fall arrest systems. On or about October 18, 2024, on the upper level of a residential building, employees were not in use of fall protection while performing framing work activities from an edge that was more than six(6) feet to the ground below.
Recent events (2)
- — I (S) $0
- — Z (S) $2837
More inspections at JOHN TORRES
ANGLETON, TX—1994-08-17 00:00:00
JOHN TORRES
View JOHN TORRES's full OSHA safety record →
More inspections in this industry (NAICS 238130)
ENCINITAS, CA—2026-07-13
LOU RIDDLE CONSTRUCTION
MERIDIAN, ID—2026-07-10
IDAHO HOMES CONSTRUCTION LLC
KIMBERLY, WI—2026-07-10
ENRIQUE RESENDIC
METTER, GA—2026-07-10
M.A.P.C CONSTRUCTION, LLC
SLINGER, WI—2026-07-10
RAMIREZ HOME BUILDERS LLC
More inspections in OK
MADILL, OK—2026-07-08
MID AMERICAN STEEL & WIRE CO., LLC
SEILING, OK—2026-06-26
GORE ENERGY
ADA, OK—2026-06-25
PAN AMERICA ELECTRIC , INC.
ADA, OK—2026-06-25
CITATION OIL & GAS CORPORATION
EDMOND, OK—2026-06-23
BRICK EXPERTS INC.
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 347825333.