Safety Incidents OSHA Severe Injury Reports · 2015–2025
3,913,242Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: ALTITUDE SOLAR LLC

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of ALTITUDE SOLAR LLC in 316 ILLINI DRIVE, EAST PEORIA, IL 61611 (NAICS 238190). OSHA activity number 347836199.

Watch Altitude Solar LLC — free Get an email when a new federal OSHA severe-injury report for Altitude Solar LLC is published. One employer, no account, unsubscribe in one click.
Establishment
ALTITUDE SOLAR LLC
Site address
316 ILLINI DRIVE
City
EAST PEORIA
State
IL
ZIP
61611
Mailing
17777 N SCOTTSDALE ROAD UNIT 1088, SCOTTSDALE, AZ 85255
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Last modified
Data loaded
NAICS code
238190
Employees
3
Ownership type
A

3 citations on file for this inspection.

1926.20 B02

Serious Gravity 5 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $3457.00 · Current $3457.00
29 CFR 1926.20(b)(2):  The employer did not initiate and maintain programs which provided for frequent and regular inspections of the job site, materials, and equipment to be made by a competent person:  On or about October 23, 2024, employees were exposed to a fall hazard of approximately 12 feet while working from the residential roof because the employer did not ensure a competent person conducted frequent and regular inspections of the worksite and equipment to identify the workplace hazards.
Recent events (1)
  • — Z (S) $3457

1926.501 B13

Serious Gravity 10 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $4839.00 · Current $4839.00
29 CFR 1926.501(b)(13):  Employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were other provisions of paragraph (b) of this section used to provide an alternative fall protection measure:  On or about October 23, 2024, employees were exposed to a fall hazard of approximately 12 feet while working from the residential roof installing solar racking components because suitable fall protection was not used.
Recent events (1)
  • — Z (S) $4839

1926.1053 B01

Serious Gravity 5 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $3457.00 · Current $3457.00
29 CFR 1926.1053(b)(1):  Portable ladders were used for access to an upper landing surface and the ladder side rails did not extend at least 3 feet (0.9 m) above the upper landing surface to which the ladder was used to gain access:  On or about October 23, 2024, employees were exposed to a fall hazard of approximately 12 feet while using a ladder to ascend and descend the roof because the side rails did not extend at least three feet above the edge of the roof.
Recent events (1)
  • — Z (S) $3457

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 347836199.