Safety Incidents OSHA Severe Injury Reports · 2015–2025
3,913,242Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: PRECISION PIPELINE SERVICES, LLC.

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of PRECISION PIPELINE SERVICES, LLC. in 4545 CREEK RD, CINCINNATI, OH 45242 (NAICS 237110). OSHA activity number 347852436.

Watch Precision Pipeline Services, LLC. — free Get an email when a new federal OSHA severe-injury report for Precision Pipeline Services, LLC. is published. One employer, no account, unsubscribe in one click.
Site address
4545 CREEK RD
City
CINCINNATI
State
OH
ZIP
45242
Mailing
10 WHILEY RD, LANCASTER, OH 43130
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
237110
Employees
5
Ownership type
A

2 citations on file for this inspection.

1926.651 C02

Other-than-serious Gravity 10 1 instance 1 exposed
Issued
Penalty
Initial $5807.00 · Current $5807.00
29 CFR  1926.651(c)(2): Means of egress from trench excavations. A stairway, ladder, ramp or other safe means of egress shall be located in trench excavations that are 4 feet (1.22 m) or more in depth so as to require no more than 25 feet (7.62 m) of lateral travel for employees.  a) On October 30, 2024, the employer did not provide a safe means of egress from the 6 ft 2 in deep trench excavation in that there was no ladder, ramp, or stairway available to use by employees inside the trench, who were performing work outside of the trench box.
Recent events (2)
  • — I (O) $5807
  • — Z (S) $5807

1926.652 A01

Other-than-serious Gravity 10 1 instance 1 exposed
Issued
Penalty
Initial $5807.00 · Current $5807.00
29 CFR  1926.652(a)(1): Each employee in an excavation shall be protected from cave-ins by an adequate protective system designed in accordance with paragraph (b) or (c) of this section.  a) On or about October 30, 2024, the employer did not ensure adequate means of conventional cave-in protection was being used to protect employees from potential collapse in and around a 6 ft 2 in deep excavation with vertical walls while taking measurements of fire main PIV fittings.
Recent events (2)
  • — I (O) $5807
  • — Z (S) $5807

View PRECISION PIPELINE SERVICES, LLC.'s full OSHA safety record →