EAGLE, ID —
OSHA Inspection: FOX FRAMING LLC
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of FOX FRAMING LLC in CORNER OF TEMPSTORD WAY AND ESCALANTE DR., EAGLE, ID 83616 (NAICS 238130). OSHA activity number 347861494.
Where did this inspection happen?
- Establishment
- FOX FRAMING LLC
- Site address
- CORNER OF TEMPSTORD WAY AND ESCALANTE DR.
- City
- EAGLE
- State
- ID
- ZIP
- 83616
- Mailing
- 992 W IDAHO AVE., MERIDIAN, ID 83642
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238130
- Employees
- 3
- Ownership type
- A
Citations
5 citations on file for this inspection.
1926.100 A
- Issued
- Abate by
- Penalty
- Initial $2765.00 · Current $1383.00 Reduced
General-duty citation text
29 CFR 1926.100(a):Employees working in areas where there was a possible danger of head injury from impact, or falling or flying objects, or from electrical shock and burns, were not protected by protective helmets: (a) On November 5th, 2024 employees were exposed to head injuries while working on the ground below framers on the roof. Abatement Note: Abatement certification is required for this item. See enclosed "Certification of Corrective Actions Worksheet."
Recent events (2)
- — I (S) $1382.5
- — Z (S) $2765
1926.102 A01
- Issued
- Abate by
- Penalty
- Initial $2074.00 · Current $0.00 Reduced
General-duty citation text
29 CFR 1926.102(a)(1):The employer did not ensure that each affected employee used appropriate eye or face protection when exposed to eye or face hazards from flying particles, molten metal, liquid chemicals, acids or caustic liquids, chemical gases or vapors, or potentially injurious light radiation. a) On November 5th, 2024 and times prior, employees using a pneumatic nail gun to install roofing material were not wearing eye protection. Abatement Note: Abatement certification is required for this item. See enclosed "Certification of Corrective Actions Worksheet."
Recent events (2)
- — I (S) $0
- — Z (S) $2074
1926.501 B13
- Issued
- Abate by
- Penalty
- Initial $4839.00 · Current $2420.00 Reduced
General-duty citation text
29 CFR 1926.501(b)(13):Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): (a) On November 5th, 2024, employees were exposed to falls between 10 and 21 feet to the ground below while performing framing activities. Abatement Note: Abatement certification and documentation is required for this item. See enclosed "Certification of Corrective Actions Worksheet."
Recent events (2)
- — I (S) $2419.5
- — Z (S) $4839
1926.1053 B01
- Issued
- Abate by
- Penalty
- Initial $4148.00 · Current $2074.00 Reduced
General-duty citation text
29 CFR 1926.1053(b)(1): Where portable ladders were used for access to an upper landing surface and the ladder's length allows, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface being accessed: (a) On November 5th, 2024, employees working on the roof of a new single-family building were using an A-frame lean safe ladder to access and exit the roof. The ladder was positioned below the access point by at least 2.5 feet. Abatement Note: Abatement certification is required for this item. See enclosed "Certification of Corrective Actions Worksheet."
Recent events (2)
- — I (S) $2074
- — Z (S) $4148
1926.1053 B13
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1926.1053(b)(13):The top or step of a stepladder was used as a step: (a) On November 5, 2024, employees used the top step of an A-frame lean safe ladder to access and exit the roof and work area. Abatement Note: Abatement certification is required for this item. See enclosed "Certification of Corrective Actions Worksheet."
Recent events (2)
- — I (S) $0
- — Z (S) $0
More inspections at FOX FRAMING LLC
FREDERICK, MD—2021-10-15 00:00:00
FOX FRAMING, LLC
URBANA, MD—2021-10-01 00:00:00
FOX FRAMING, LLC
FREDERICK, MD—2021-07-22 00:00:00
FOX FRAMING, LLC
View FOX FRAMING LLC's full OSHA safety record →
More inspections in this industry (NAICS 238130)
FAIRHOPE, AL—2026-07-16
FRANCISCO ARES
WOODHAVEN, MI—2026-07-16
G.J. PERELLI CO., L.L.C.
PHILADELPHIA, PA—2026-07-16
URUS CONSTRUCTION CORPORATION
BERLIN, NJ—2026-07-16
URUS CONSTRUCTION CORPORATION
MERIDIAN, ID—2026-07-15
TRIPLE R CONSTRUCTION LLC
More inspections in ID
BOISE, ID—2026-07-16
RAYMOND MANAGEMENT COMPANY
MERIDIAN, ID—2026-07-15
TRIPLE R CONSTRUCTION LLC
MERIDIAN, ID—2026-07-15
MIRZON CONSTRUCTION LLC
MERIDIAN, ID—2026-07-15
EASTER SEALS - GOODWILL NORTHERN ROCKY MOUNTAINS
NAMPA, ID—2026-07-15
ELITE STEEL ERECTORS, LLC
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 347861494.