Safety Incidents OSHA Severe Injury Reports · 2015–2025
4,113,118Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: DINIZ DESIGN

Planned inspection · Health discipline

On , OSHA opened a planned health inspection of DINIZ DESIGN in 11962 LAKELAND PARK BOULEVARD, BATON ROUGE, LA 70809 (NAICS 327991). OSHA activity number 347880262.

Watch Diniz Design — free Get an email when a new federal OSHA severe-injury report for Diniz Design is published. One employer, no account, unsubscribe in one click.
Establishment
DINIZ DESIGN
Site address
11962 LAKELAND PARK BOULEVARD
City
BATON ROUGE
State
LA
ZIP
70809
Mailing
11962 LAKELAND PARK BOULEVARD, BATON ROUGE, LA 70809
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Last modified
Data loaded
NAICS code
327991
Employees
4
Ownership type
A

4 citations on file for this inspection.

1903.19 C01

Other-than-serious 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $398.00 · Current $398.00
29 CFR  1903.19(c)(1): The employer did not certify to OSHA, within 10 calendar days after the abatement date, that the cited violation had been abated:  a) On or about September 29, 2025, the employer failed to submit certification of corrective action for Citation 1, Item 1 and Item 2, and Citation 2, Item 1, issued on April 25, 2025 with an abatement due date of May 14, 2025.
Recent events (1)
  • — Z (O) $398

1910.243 C03

Serious Gravity 5 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $4256.00 · Current $4256.00
29 CFR  1910.243(c)(3):Abrasive wheels used on vertical portable grinder(s) (right angle head grinders) were not provided with safety guard(s) having a maximum exposure angle of 180 degrees and located between the operator and wheel:  a) On or about November 11, 2024 on a workbench at the back of the fabrication shop, employees used Makita angle grinders that did not have wheel guards installed.
Recent events (1)
  • — Z (S) $4256

1910.334 A02 I

Serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $2837.00 · Current $2837.00
29 CFR  1910.334(a)(2)(i): Portable cord and plug connected equipment and flexible cord sets (extension cords) were not visually inspected before use on any shift for external defects (such as loose parts, deformed and missing pins, or damage to outer jacket or insulation) and for evidence of possible internal damage (such as pinched or crushed outer jacket):  a) On or about November 11, 2024, on a workbench at the back of the fabrication shop, employees used Makita angle grinders that had damaged outer jacket and was wrapped with electrical tape.
Recent events (1)
  • — Z (S) $2837

1910.134 K06

Other-than-serious 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR  1910.134(k)(6): The employer did not provide the basic advisory information on respirators, as presented in Appendix D of 29 CFR 1910.134, in written or oral format to employees who wear respirators when such use was not required by the employer:  a) On or about November 11, 2024 employees in the fabrication shop area voluntarily utilized HDX N95 respirators without first reviewing Appendix D of 29 CFR 1910.134.
Recent events (1)
  • — Z (O) $0

OXYCHEM