MEADVILLE, PA —
OSHA Inspection: GREDE
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of GREDE in 18771 MILL STREET, MEADVILLE, PA 16335 (NAICS 331523). OSHA activity number 347883605.
Where did this inspection happen?
- Establishment
- GREDE
- Site address
- 18771 MILL STREET
- City
- MEADVILLE
- State
- PA
- ZIP
- 16335
- Mailing
- 18771 MILL STREET, MEADVILLE, PA 16335
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- A
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 331523
- Employees
- 225
- Ownership type
- A
Citations
4 citations on file for this inspection.
1910.147 E03
- Issued
- Abate by
- Penalty
- Initial $16000.00 · Current $5000.00 Reduced
General-duty citation text
29 CFR 1910.147(e)(3): Each lockout or tagout device was not removed from each energy isolating device by the employee who applied the device: A) Grede DBA Grede Casting Integrity on or about September 27 at the address of 18771 Mill Street, Meadville, PA: Maintenance removed Lockout devices from the energy isolating devices for Shaker #20. The lockout devices were removed by employees who did not apply the devices. The procedures specified in the 29 CFR 1910.147(e)(3)(ii) through 29 CFR 1910.147(e)(3)(iii) were not followed when the Lockout devices were removed.
Recent events (2)
- — I (S) $5000
- — Z (S) $16000
1910.253 B04 I
- Issued
- Abate by
- Penalty
- Initial $7093.00 · Current $5000.00 Reduced
General-duty citation text
29 CFR 1910.253(b)(4)(i): Oxygen cylinders were stored near highly combustible material, especially oil and grease; or near reserve stocks of carbide and acetylene or other fuel-gas cylinders, or near other substance likely to cause or accelerate fire: A) Grede DBA Grede Casting Integrity on or about November 15 at the address of 18771 Mill Street, Meadville, PA: full oxygen cylinders were stored directly next to propane cylinders at the main entrance of the facility. The cylinders were stored within 2 feet of each other with no fire barrier.
Recent events (2)
- — I (S) $5000
- — Z (S) $7093
1910.101 B
- Issued
- Abate by
- Penalty
- Initial $7093.00 · Current $5000.00 Reduced
General-duty citation text
29 CFR 1910.101(b):The in-plant handling, storage, and utilization of all compressed gases in cylinders, portable tanks, rail tankcars, or motor vehicle cargo tanks were not in accordance with Compressed Gas Association Pamphlet P-1-1965, which is incorporated by reference as specified in CFR 1910.6: A) Grede DBA Grede Casting Integrity on or about November 15 at the address of 18771 Mill Street, Meadville, PA: A free standing oxygen cylinder was at the side of the building without being secured.
Recent events (2)
- — I (O) $5000
- — Z (S) $7093
1910.106 B06
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.106(b)(6): In locations where flammable vapors may be present, precautions were not taken to prevent ignition by eliminating or controlling sources of ignition. Sources of ignition may include open flames, lightning, smoking, hot surfaces, frictional heat, sparks (static, electrical, and mechanical), spontaneous ignition, chemical and physical-chemical reactions, and radiant heat: A) Grede DBA Grede Casting Integrity on or about November 15 at the address of 18771 Mill Street, Meadville, PA: Employees operate outside shaker #20 area with flammables next to open flame casting dryers. The heaters were in use approximately 5-feet away from an open storage cabinet containing flammables.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at GREDE
MEADVILLE, PA—2025-01-08
GREDE
View GREDE's full OSHA safety record →
More inspections in this industry (NAICS 331523)
SUN VALLEY, CA—2026-06-22
KENWALT DIE CASTING COMPANY
GALESBURG, IL—2026-06-03
ALCAST AQUISITION COMPANY LLC
FRANKLIN PARK, IL—2026-05-29
R.C.M. INDUSTRIES, INC. DBA AALLIED DIE CASTING COMPANY OF ILLINOIS
GREENE, NY—2026-05-22
GREENE BRASS & ALUMINUM FOUNDRY
NORTHBROOK, IL—2026-05-20
ACME ALLIANCE LLC
More inspections in PA
MILTON, PA—2026-07-10
HOMETOWN FOODS CHEF BOYARDEE CO.
SUNBURY, PA—2026-07-10
DEMPSEY UNIFORM & LINEN SUPPLY, INC
LANDISVILLE, PA—2026-07-10
FAIRVIEW DEMOLITION LLC
YORK, PA—2026-07-10
AMERICAN SPECIALTY SYSTEMS INC.
WILLIAMSPORT, PA—2026-07-10
INTERNATIONAL PAINT PROS
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 347883605.