Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,214Inspections Most recent open 2026-07-16 Last loaded 2026-07-20

OSHA Inspection: WIL SON PALLET LLC

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of WIL SON PALLET LLC in 1858 N. CR 1300 E, SULLIVAN, IL 61951 (NAICS 321920). OSHA activity number 347886152.

Watch WIL SON Pallet LLC — free Get an email when a new federal OSHA severe-injury report for WIL SON Pallet LLC is published. One employer, no account, unsubscribe in one click.
Establishment
WIL SON PALLET LLC
Site address
1858 N. CR 1300 E
City
SULLIVAN
State
IL
ZIP
61951
Mailing
1858 N. CR 1300 E, SULLIVAN, IL 61951
Inspection type
Referral (C)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
321920
Employees
44
Ownership type
A

6 citations on file for this inspection.

1910.147 C04 II A

Other-than-serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $8276.00 · Current $0.00 Reduced
29 CFR 1910.147(c)(4)(ii)(A): The energy control procedures did not contain a specific statement on the intended use of the procedure:  On or about November 14, 2024, employees were exposed to unexpected start-up or release of stored energy while performing servicing and maintenance activities, and the procedures for Trim Saw on Line 2 did not contain a specific statement on the intended use of the procedures.
Recent events (2)
  • — I (O) $0
  • — Z (S) $8276

1910.147 C04 II B

Other-than-serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $8276.00 · Current $4966.00 Reduced
29 CFR 1910.147(c)(4)(ii)(B): The energy control procedures did not clearly and specifically outline the steps for shutting down, isolating, blocking and securing machines or equipment to control hazardous energy:  On or about November 14, 2024, an employee was servicing the Trim Saw on Line 2, and the procedures did not clearly identify how to shut down and isolate the energy sources.
Recent events (2)
  • — I (O) $4965.6
  • — Z (S) $8276

1910.147 C04 II C

Deleted Serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $8276.00 · Current $0.00 Reduced
29 CFR 1910.147(c)(4)(ii)(C): The energy control procedure did not clearly and specifically outline the steps for placement, removal and transfer of lockout devices or tagout devices and the responsibility for them:  On or about November 14, 2024, an employee servicing the Trim Saw on Line 2, did not clearly and specifically outline the steps for placement, removal and transfer of lockout devices or tagout devices and the responsibility for them.
Recent events (2)
  • — I (S) $0
  • — Z (S) $8276

1910.147 C04 II D

Other-than-serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $8276.00 · Current $4966.00 Reduced
29 CFR 1910.147(c)(4)(ii)(D): The energy control procedures did not clearly and specifically outline the requirements for testing a machine or equipment to determine and verify the effectiveness of lockout devices, tagout devices, and other energy control:  Employees were exposed to unexpected start-up or release of stored energy while performing servicing and maintenance activities.  On or about November 14, 2024, an employee was servicing the Trim Saw on Line 2, and the procedures did not clearly outline how to verify the effectiveness of the lockout.
Recent events (2)
  • — I (O) $4965.6
  • — Z (S) $8276

1910.147 C07 I A

Other-than-serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $8276.00 · Current $0.00 Reduced
29 CFR 1910.147(c)(7)(i)(A): Each authorized employee had not received training in the recognition of applicable hazardous energy sources, the type and magnitude of the energy available in the workplace, and the methods and means necessary for energy isolation and control:  On or about November 14, 2024, an employee was servicing the Trim Saw on Line 2, and the employer did not ensure that each employee engaged in servicing and maintenance tasks were trained as a lockout authorized employee to safely de-energize machine or equipment prior to starting work.
Recent events (2)
  • — I (O) $0
  • — Z (S) $8276

1910.147 D

Serious Gravity 10 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $11585.00 · Current $8109.00 Reduced
29 CFR 1910.147(d): The established procedure for the application of energy control (the lockout or tagout procedures) did not cover the actions listed in and was not done in sequence as required by 29 CFR 1910.147(d)(1)-(6):   On or about November 14, 2024, an employee was exposed to hazardous energy sources when performing maintenance and servicing, including, but not limited to, the Trim Saw on Line 2, because the employer did not cover the action listed in and was not done in sequence as required by 29 CFR 1910.147(d)(1)-(6).  Employees who performed servicing and maintenance were not required to:  (1)	Know the type and magnitude of the energy, the hazards of the energy to be controlled, and the method or means to control the energy,  (2)	Turn off and shut down the machine,  (3)	Physically locate and operate energy isolating devices in such a manner as to isolate the machine or equipment from the energy source,  (4)	Affix lockout or tagout devices to each energy isolating device,  (5)	Prior to starting work on machines that have been locked out or tagged out, verify that isolation and deenergization of the machine or equipment have been accomplished.  (6)	Prior to starting work on machines that have been locked out or tagged out, verify that isolation and deenergization of the machine or equipment have been accomplished.
Recent events (2)
  • — I (S) $8108.8
  • — Z (S) $11585

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 347886152.