Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,214Inspections Most recent open 2026-07-16 Last loaded 2026-07-20

OSHA Inspection: WOESTE REMODELING, INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of WOESTE REMODELING, INC. in 1624 SCENICVIEW LANE, MILFORD, OH 45150 (NAICS 236118). OSHA activity number 347896524.

Watch Woeste Remodeling, INC. — free Get an email when a new federal OSHA severe-injury report for Woeste Remodeling, INC. is published. One employer, no account, unsubscribe in one click.
Site address
1624 SCENICVIEW LANE
City
MILFORD
State
OH
ZIP
45150
Mailing
7243 BRIDGES ROAD, CINCINNATI, OH 45230
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
236118
Employees
2
Ownership type
A

2 citations on file for this inspection.

1926.501 B13

Serious Gravity 10 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $4965.00 · Current $2000.00 Reduced
29 CFR 1926.501(b)(13):"Residential construction." Each employee engaged in residential construction activities 6 feet (1.8 m) or more above lower levels shall be protected by guardrail systems, safety net system, or personal fall arrest system unless another provision in paragraph (b) of this section provides for an alternative fall protection measure. Exception: When the employer can demonstrate that it is infeasible or creates a greater hazard to use these systems, the employer shall develop and implement a fall protection plan which meets the requirements of paragraph (k) of 1926.502. Note: There is a presumption that it is feasible and will not create a greater hazard to implement at least one of the above-listed fall protection systems. Accordingly, the employer has the burden of establishing that it is appropriate to implement a fall protection plan which complies with 1926.502(k) for a particular workplace situation, in lieu of implementing any of those systems.  a) On November 20, 2024, the employer did not ensure that an employee was utilizing a fall protection system while conducting exterior trim work on a newly constructed residential structure. The employee was exposed to a fall height of 9'2'' with a roof pitch of 6/12.
Recent events (2)
  • — I (S) $2000
  • — Z (S) $4965

1926.1053 B01

Serious Gravity 10 1 instance 1 exposed
Issued
Penalty
Initial $4965.00 · Current $0.00 Reduced
29 CFR 1926.1053(b)(1):When portable ladders are used for access to an upper landing surface, the ladder side rails shall extend at least 3 feet (.9 m) above the upper landing surface to which the ladder is used to gain access; or, when such an extension is not possible because of the ladder's length, then the ladder shall be secured at its top to a rigid support that will not deflect, and a grasping device, such as a grabrail, shall be provided to assist employees in mounting and dismounting the ladder. In no case shall the extension be such that ladder deflection under a load would, by itself, cause the ladder to slip off its support.  a) On November 20, 2024, the employer failed to ensure that an extension ladder used for roof access extended at least 36 inches above the upper landing surface. As a result, an employee was exposed to a fall hazard of 9'2'' to the ground below.
Recent events (2)
  • — I (S) $0
  • — Z (S) $4965

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 347896524.