Safety Incidents OSHA Severe Injury Reports · 2015–2025
4,113,118Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: BRICK RESTORATION, INC.

Federal Agency inspection · Safety discipline

On , OSHA opened a federal Agency safety inspection of BRICK RESTORATION, INC. in 28 LAKEWOOD LN, SEABROOK, TX 77586 (NAICS 238140). OSHA activity number 347899759.

Watch Brick Restoration, INC. — free Get an email when a new federal OSHA severe-injury report for Brick Restoration, INC. is published. One employer, no account, unsubscribe in one click.
Site address
28 LAKEWOOD LN
City
SEABROOK
State
TX
ZIP
77586
Mailing
8830 EMNORA LANE, HOUSTON, TX 77080
Inspection type
Federal Agency (M)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Last modified
Data loaded
NAICS code
238140
Employees
35
Ownership type
A

6 citations on file for this inspection.

1926.451 A01

Serious Gravity 5 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $8276.00 · Current $8276.00
29 CFR 1926.451(a)(1): Scaffold(s) and scaffold(s) component(s) were not capable of supporting, without failure, its own weight and at least four times the maximum intended load applied or transmitted to it:  (a) On or about November 21, 2024, at the jobsite, where an employee was using a scaffold hoist arm to lift a concrete wall panel that exceeded its load capacity while preforming replacement activities.
Recent events (2)
  • — I (S) $8276
  • — Z (S) $8276

1926.451 B01

Serious Gravity 10 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $11585.00 · Current $11585.00
29 CFR 1926.451(b)(1): Each platform on all working levels of scaffolds was not fully planked or decked between the front uprights and the guardrail supports as specified in paragraphs 1926.451(b)(1)(i)-(ii)  (a) On or about November 21, 2024, at the jobsite, where an employee was lifting a wall panel from the second tier of a two-tiered scaffold that was not fully planked.
Recent events (2)
  • — I (S) $11585
  • — Z (S) $11585

1926.451 C01 III

Deleted Serious Gravity 10 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $11585.00 · Current $0.00 Reduced
29 CFR 1926.451(c)(1)(iii): Ties, guys, braces, or outriggers shall be used to prevent the tipping of supported scaffolds in all circumstances where an eccentric load, such as a cantilevered work platform, is applied or is transmitted to the scaffold.  (a) On or about November 21, 2024, at the jobsite, where employee(s) was using a winch, attached to the scaffold by a hoisting arm on the corner of the scaffold, to lift a concrete wall panel without ties, guys, braces or outriggers.
Recent events (2)
  • — I (S) $0
  • — Z (S) $11585

1926.451 F07

Deleted Serious Gravity 10 1 instance 6 exposed
Issued
Abate by
Penalty
Initial $11585.00 · Current $0.00 Reduced
29 CFR 1926.451(f)(7): Scaffolds were not erected, moved, dismantled, or altered, by trained and experienced employees under the supervision and direction of a competent person qualified in scaffold erection, moving, dismantling or alteration:   (a) On or about November 21, 2025, at the jobsite, where an employee was operating a winch from the second tier of a scaffold that was not erected under the supervision and direction of a competent person qualified in scaffold erection.
Recent events (2)
  • — I (S) $0
  • — Z (S) $11585

1926.454 B

Other-than-serious Gravity 10 1 instance 6 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR  1926.454(b): The employer did not have each employee involved in erecting, disassembling, moving, operating, repairing, maintaining, or inspecting a scaffold trained by a competent person to recognize any hazards associated with the work in question.   (a) On or about November 21, 2025, at the jobsite, where an employee was lifting a wall panel from the second tier of a scaffold without training by a competent person to recognize hazards with the erection and operation of the scaffold.
Recent events (2)
  • — I (O) $0
  • — Z (S) $0

1926.451 B01

Serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $8276.00 · Current $0.00 Reduced
1926.451(b)(1)  Each platform on all working levels of scaffolds shall be fully planked or decked between the front uprights and the guardrail supports as follows: 29 CFR 1926.451(g)(1): Employees on scaffolds more than 10 feet (3.1 m) above a lower level were not protected from falling to that lower level by fall protection established in paragraphs (g)(1)(i)-(vii) of this section:  (a) On or about November 21, 2024, at the jobsite, where an employee was operating a winch from the second tier of a two-tier scaffold, over 10 feet, without any fall protection system.
Recent events (2)
  • — I (S) $0
  • — Z (S) $8276

View BRICK RESTORATION, INC.'s full OSHA safety record →