Safety Incidents OSHA Severe Injury Reports · 2015–2025
4,113,118Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: JSS STEEL CO., INC.

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of JSS STEEL CO., INC. in 26400 RICHMOND ROAD, BEDFORD HEIGHTS, OH 44146 (NAICS 423510). OSHA activity number 347914962.

Watch JSS Steel CO., INC. — free Get an email when a new federal OSHA severe-injury report for JSS Steel CO., INC. is published. One employer, no account, unsubscribe in one click.
Establishment
JSS STEEL CO., INC.
Site address
26400 RICHMOND ROAD
City
BEDFORD HEIGHTS
State
OH
ZIP
44146
Mailing
26400 RICHMOND ROAD, BEDFORD HEIGHTS, OH 44146
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
423510
Employees
60
Ownership type
A

4 citations on file for this inspection.

1910.147 C05 II

Other-than-serious Gravity 5 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $8276.00 · Current $4138.00 Reduced
29 CFR 1910.147(c)(5)(ii): Lockout devices and tagout devices were not singularly identified:   On or about December 3, 2024, the employer failed to ensure that when maintenance tasks were performed by authorized employees, that the lockout/tagout devices were singularly identified with the name of the employee who had isolated the electrical energy source on the Tsune TK5C Circular Saw, Machine # 5 (Serial # 01616).
Recent events (2)
  • — I (O) $4138
  • — Z (S) $8276

1910.147 C06 I

Serious Gravity 5 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $8276.00 · Current $4138.00 Reduced
29 CFR 1910.147(c)(6)(i): The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed:  On or about December 3, 2024, the employer did not ensure periodic inspections of energy control procedures were conducted annually, including a review of each authorized employee's responsibilities under the energy control procedures. Authorized employees are required to conduct and direct service and maintenance activities on machinery including the Tsune TK50, Amanda CMII 75DG/100DG, & Nishijimax NHC-100ND, with energy sources including, but not limited to, Electrical, Pneumatic, and Hydraulic.
Recent events (2)
  • — I (S) $4138
  • — Z (S) $8276

1910.212 A01

Serious Gravity 10 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $11585.00 · Current $5724.00 Reduced
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks:  On or about November 24, 2024, the employer did not ensure one or more methods of machine guarding were provided to protect the operator working at the Tsune TK5C Circular Saw, Machine # 5 (Serial # 01616), when employees cutting steel have the ability to have their hands within the point of operation while the blade is in operation. The existing guard was ineffective and resulted in an amputation injury.
Recent events (2)
  • — I (S) $5724
  • — Z (S) $11585

1910.38 B

Other-than-serious 1 instance 58 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.38(b): An emergency action plan was not in writing, kept in the workplace, and available to employees for review:  On or about December 3, 2024, the employer failed to keep an emergency action plan in writing in the workplace and available to employees for review. Approximately 60 employees currently work within the facility.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 347914962.