READING, PA —
OSHA Inspection: JERICHO GROUP, LLC
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of JERICHO GROUP, LLC in 2120 FAIRMONT AVE MITSUBISHI CHEMICAL ADVANCED MATERIALS INC., READING, PA 19612 (NAICS 237110). OSHA activity number 347958472.
Where did this inspection happen?
- Establishment
- JERICHO GROUP, LLC
- Site address
- 2120 FAIRMONT AVE MITSUBISHI CHEMICAL ADVANCED MATERIALS INC.
- City
- READING
- State
- PA
- ZIP
- 19612
- Mailing
- 1003 MORGANTOWN ROAD, READING, PA 19607
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 237110
- Employees
- 2
- Ownership type
- A
Citations
4 citations on file for this inspection.
1926.652 A01
- Issued
- Abate by
- Penalty
- Initial $5675.00 · Current $0.00 Reduced
General-duty citation text
29 CFR 1926.652(a)(1): Each employee in an excavation was not protected from cave-ins by an adequate protective system designed in accordance with 29 CFR 1926.652 (b) or (c): (a) 2120 Fairmont Ave, Reading, PA; Basement boiler room - On or about December 31, 2024, employees had entered a trench measuring approximately 45 feet long, 55 inches wide and between 3.9 feet and 8.5 feet deep without cave-in protection in place, which exposed the employee(s) to an engulfment hazard. (b) 2120 Fairmont Ave, Reading, PA; Pit on the exterior of the basement boiler room - On or about January 2, 2025, employees had entered an excavation measuring approximately 5 feet wide by 5 feet long and 9 feet deep without cave-in protection in place, which exposed the employee(s) to an engulfment hazard. Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (2)
- — I (S) $0
- — Z (S) $5675
1926.652 A02
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $6000.00
General-duty citation text
29 CFR 1926.652(a)(2): Protective systems did not have the capacity to resist without failure all loads that were intended or could reasonably be expected to be applied or transmitted to the system: (a) 2120 Fairmont Ave, Reading, PA; Basement boiler room - On or about January 2, 2025, the employer had installed trench shoring which did not have the capacity to resist a side load from the trench wall without failure due to being constructed from wood planks which were nailed together. Employee(s) were exposed to an engulfment hazard in the event of a trench collapse. Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (2)
- — I (S) $6000
- — Z (S) $0
1926.651 G01 I
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1926.651(g)(1)(i): Where oxygen deficiency (atmosphere containing less than 19.5 percent oxygen) or a hazardous atmosphere existed or could reasonably be expected to exist, such as in excavations in landfill areas or excavations the in areas where hazardous substances are stored nearby, the atmospheres in the excavation shall be tested before employees enter excavations greater than 4 feet (1.22 m) in depth: (a) 2120 Fairmont Ave, Reading, PA; Basement boiler room - On or about December 31, 2024, employees had entered a trench measuring approximately 45 feet long, 55 inches wide and between 3.9 feet and 8.5 feet deep without first performing a test of the atmosphere in the trench. Employees were exposed to respiratory hazard(s) caused by potential exposure to hydrogen sulfide and methane. (b) 2120 Fairmont Ave, Reading, PA; Pit on the exterior of the basement boiler room - On or about January 2, 2025, employees had entered an excavation measuring approximately 5 feet wide by 5 feet long and 9 feet deep without first performing a test of the atmosphere in the excavation. Employees were exposed to respiratory hazard(s) caused by potential exposure to hydrogen sulfide and methane. Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.1053 B04
- Issued
- Abate by
- Penalty
- Initial $2837.00 · Current $0.00 Reduced
General-duty citation text
29 CFR 1926.1053(b)(4):Ladder(s) were used for purposes other than the purpose for which they were designed: (a) 2120 Fairmont Ave, Reading, PA; Pit on the exterior of the basement boiler room - On or about January 2, 2025, employees had entered an excavation measuring approximately 5 feet wide by 5 feet long and 8 to 9 feet deep using a 6-foot Werner a-frame step ladder in the closed position to enter and exit the excavation. Employees were exposed to a fall hazard. Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (2)
- — I (S) $0
- — Z (S) $2837
More inspections in this industry (NAICS 237110)
CHESAPEAKE, VA—2026-07-10
A&W CONTRACTORS, INC.
BRIDGEPORT, CT—2026-07-10
WRR, INC.
MARYSVILLE, WA—2026-07-09
WA317992011 - BDZ DEVELOPERS INC
PEORIA, IL—2026-07-08
WALTERS WATERWORKS LLC DBA MR. ROOTER PLUMBING OF PEORIA
TAMPA, FL—2026-07-08
DALLAS 1 CONSTRUCTION AND DEVELOPMENT, INC.
More inspections in PA
MILTON, PA—2026-07-10
HOMETOWN FOODS CHEF BOYARDEE CO.