Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,214Inspections Most recent open 2026-07-16 Last loaded 2026-07-20

OSHA Inspection: WEIR KITCHENS INC.

Follow-up inspection · Safety discipline

On , OSHA opened a follow-up safety inspection of WEIR KITCHENS INC. in 350 SOUTH WINDING ROAD, DOVER, PA 17315 (NAICS 337110). OSHA activity number 347964884.

Watch Weir Kitchens INC. — free Get an email when a new federal OSHA severe-injury report for Weir Kitchens INC. is published. One employer, no account, unsubscribe in one click.
Establishment
WEIR KITCHENS INC.
Site address
350 SOUTH WINDING ROAD
City
DOVER
State
PA
ZIP
17315
Mailing
350 SOUTH WINDING ROAD, DOVER, PA 17315
Inspection type
Follow-up (F)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Last modified
Data loaded
NAICS code
337110
Employees
12
Ownership type
A

9 citations on file for this inspection.

5(a)(1)

Repeat Gravity 5 2 instances 3 exposed
Issued
Abate by
Penalty
Initial $11350.00 · Current $11350.00
OSH ACT of 1970 Section (5)(a)(1): The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees engaged in woodworking operations were exposed to combustible dust explosion, deflagration, and/or other fire hazards from combustible wood dust.  a) 350 South Winding Road DOVER, PA 17315, Cabinet Room - Combustible wood dust was not removed at least daily from indoor enclosureless dust collectors, such as a Central Machinery (Model 45378) and Grizzly Industrial wall mounted (Model G0710), on or about January 7, 2025.  b) 350 South Winding Road DOVER, PA 17315, Facility-Wide - The employer did not provide for effective capture and control of combustible wood dust generated during the operation of woodworking equipment in the Cabinet Room, Sanding Room, and Door Room, on or about January 7, 2025.  The Weir Kitchens Inc. was previously cited for a violation of this occupational safety and health standard or its equivalent standard OSH ACT of 1970 Section (5)(a)(1), which was contained in OSHA inspection number 1705601, citation number 1, item number 1 and was affirmed as a final order on April 25, 2024, with respect to a workplace located at 350 South Winding Road Dover, PA 17315.  Abatement certification and documentation required within 10 days after abatement date. The certification shall include a statement that abatement is complete, the date and method of abatement, and state that employees and their representatives were informed of this abatement. Abatement documentation shall include documents demonstrating that abatement is complete, such as evidence of the purchase or repair of equipment, photographic or video evidence of abatement or other written records.
Recent events (2)
  • — C (R) $11350
  • — Z (R) $11350

1910.22 A01

Repeat Gravity 5 3 instances 3 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.22(a)(1):29 CFR 1910.22(a)(1): The employer did not ensure that all places of employment, passageways, storerooms, service rooms, and walking-working surfaces are kept in a clean, orderly, and sanitary condition.  a) 350 South Winding Road DOVER, PA 17315, Cabinet Room - Fugitive combustible wood dust had accumulated on walls, electrical conduit, outlets and normal lighting snap switches, overhead lighting, steel beams and ductwork, and on and around woodworking equipment and dust collection systems, exposing employees to fire and explosion hazards, on or about January 7, 2025.  b) 350 South Winding Road DOVER, PA 17315, Sanding Room - Fugitive combustible wood dust had accumulated on walls, electrical conduit, outlets and normal lighting snap switches, overhead lighting and ductwork, storage racks and worktables, and on and around woodworking equipment, and dust collection systems, exposing employees to fire and explosion hazards, on or about January 7, 2025.  c) 350 South Winding Road DOVER, PA 17315, Door Room - Fugitive combustible wood dust had accumulated on walls, electrical conduit and outlets, and on and around woodworking equipment, exposing employees to fire and explosion hazards, on or about January 7, 2025.  The Weir Kitchens Inc. was previously cited for a violation of this occupational safety and health standard or its equivalent standard 1910.22(a)(1), which was contained in OSHA inspection number 1705601, citation number 1, item number 2, Group Letter a, and was affirmed as a final order on April 25, 2024, with respect to a workplace located at 350 South Winding Road DOVER, PA 17315.  Abatement certification and documentation required within 10 days after abatement date. The certification shall include a statement that abatement is complete, the date and method of abatement, and state that employees and their representatives were informed of this abatement. Abatement documentation shall include documents demonstrating that abatement is complete, such as evidence of the purchase or repair of equipment, photographic or video evidence of abatement or other written records.
Recent events (2)
  • — C (R) $0
  • — Z (R) $0

1910.22 A02

Repeat Gravity 5 2 instances 3 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.22(a)(2):29 CFR 1910.22(a)(2): The employer did not ensure that the floor of each workroom is maintained in a clean and, to the extent feasible, in a dry condition. The employer did not ensure that when wet processes are used, drainage is be maintained and, to the extent feasible, dry standing places, such as false floors, platforms, and mats are provided.  a) 350 South Winding Road DOVER, PA 17315, Cabinet Room - Fugitive combustible wood dust had accumulated greater than 1/8th inch in depth on the floor exposing employees to fire and explosion hazards, on or about   b) 350 South Winding Road DOVER, PA 17315, Sanding Room - Fugitive combustible wood dust greater than 1/8th inch in depth had accumulated on the floor, exposing employees to fire and explosion hazards, on or about   The Weir Kitchens Inc. was previously cited for a violation of this occupational safety and health standard or its equivalent standard 1910.22(a)(2), which was contained in OSHA inspection number 1705601, citation number 1, item number 2, Group Letter b, and was affirmed as a final order on April 25, 2024, with respect to a workplace located at 350 South Winding Road DOVER, PA 17315.  Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (2)
  • — C (R) $0
  • — Z (R) $0

1910.307 C

Repeat Gravity 5 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00

Hazardous substances E101

29 CFR 1910.307(c): Equipment, wiring methods, and installations of equipment in hazardous (classified) locations were not intrinsically safe, approved for the hazardous (classified) location, or safe for the hazardous (classified) location.  a) 350 South Winding Road DOVER, PA 17315, Facility-Wide - Employees used woodworking equipment, such as but not limited to, saws, sanders, a wood planer and wood shaper, which generated wood dust (a Class II combustible dust). The facility had general purpose wiring, receptacles, circuit breaker panels, disconnect switch, overhead lighting, a portable radio and fan, etc., which were not approved for Class II locations, exposing employees to fire and explosion hazards, on or about   The Weir Kitchens Inc. was previously cited for a violation of this occupational safety and health standard or its equivalent standard 1910.22(a)(2), which was contained in OSHA inspection number 1705601, citation number 1, item number 10 and was affirmed as a final order on April 25, 2024, with respect to a workplace located at 350 South Winding Road DOVER, PA 17315.  Abatement certification and documentation required within 10 days after abatement date. The certification shall include a statement that abatement is complete, the date and method of abatement, and state that employees and their representatives were informed of this abatement. Abatement documentation shall include documents demonstrating that abatement is complete, such as evidence of the purchase or repair of equipment, photographic or video evidence of abatement or other written records.
Recent events (2)
  • — C (R) $0
  • — Z (R) $0

1910.213 A15

Repeat Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $7566.00 · Current $7566.00
29 CFR 1910.213(a)(15): Combs (featherboards) or suitable jigs were not provided at the workplace for use when a standard guard could not be used, as in dadoing, grooving, jointing, moulding, and rabbeting:  a) 350 South Winding Road DOVER, PA 17315, Cabinet Room - Employees were exposed to amputation hazards while engaged in wood cutting operations, such as dadoing, while utilizing an unguarded Delta Rockwell 10" Unisaw without a comb or featherboard, on or about January 7, 2025.  The Weir Kitchens Inc. was previously cited for a violation of this occupational safety and health standard or its equivalent standard 1910.213(a)(15), which was contained in OSHA inspection number 1705601, citation number 1, item number 4, Group Letter b, and was affirmed as a final order on April 25, 2024, with respect to a workplace located at 350 South Winding Road DOVER, PA 17315.  Abatement certification and documentation required within 10 days after abatement date. The certification shall include a statement that abatement is complete, the date and method of abatement, and state that employees and their representatives were informed of this abatement. Abatement documentation shall include documents demonstrating that abatement is complete, such as evidence of the purchase or repair of equipment, photographic or video evidence of abatement or other written records.
Recent events (2)
  • — C (R) $7566
  • — Z (R) $7566

1910.305 B01 II

Repeat Gravity 1 2 instances 2 exposed
Issued
Penalty
Initial $5674.00 · Current $5674.00
29 CFR 1910.305(b)(1)(ii): Unused openings in boxes, cabinets, or fittings were not effectively closed:  a) 350 South Winding Road DOVER, PA 17315, Cabinet Room - A knockout plug was missing on an outlet between the General table saw (Model 350) and Grizzly dust collector exposing employees to combustible dust explosion hazards and electrical shock, on or about January 7, 2025.  b) 350 South Winding Road DOVER, PA 17315, Door Room - The face plate on a 20amp outlet/toggle switch, behind the Bridgewood BW-3S wood shaper, was not effectively closed in that the toggle switch opening was taped over exposing employees to combustible dust explosion hazards and electrical shock, on or about January 7, 2025.  The Weir Kitchens Inc. was previously cited for a violation of this occupational safety and health standard or its equivalent standard 1910.305(b)(1)(ii), which was contained in OSHA inspection number 1705601, citation number 1, item number 8 and was affirmed as a final order on April 25, 2024, with respect to a workplace located at 350 South Winding Road DOVER, PA 17315.  Abatement certification and documentation required within 10 days after abatement date. The certification shall include a statement that abatement is complete, the date and method of abatement, and state that employees and their representatives were informed of this abatement. Abatement documentation shall include documents demonstrating that abatement is complete, such as evidence of the purchase or repair of equipment, photographic or video evidence of abatement or other written records.
Recent events (2)
  • — C (R) $5674
  • — Z (R) $5674

1910.1200 H03 II

Repeat Gravity 5 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $7566.00 · Current $7566.00
29 CFR 1910.1200(h)(3)(ii): Employees were not trained on the physical, health, simple asphyxiation, combustible dust, and pyrophoric gas hazards, as well as hazards not otherwise classified, of the chemicals in the work area.  a) 350 South Winding Road DOVER, PA 17315, Facility-Wide - Employees were exposed to fire and explosion hazards without having been trained on the physical and health hazards of the combustible dust in their work area, on or about January 7, 2025.  The Weir Kitchens Inc. was previously cited for a violation of this occupational safety and health standard or its equivalent standard 1910.1200(h)(3)(ii), which was contained in OSHA inspection number 1705601, citation number 1, item number 11 and was affirmed as a final order on April 25, 2024, with respect to a workplace located at 350 South Winding Road DOVER, PA 17315.  Abatement certification and documentation required within 10 days after abatement date. The certification shall include a statement that abatement is complete, the date and method of abatement, and state that employees and their representatives were informed of this abatement. Abatement documentation shall include documents demonstrating that abatement is complete, such as evidence of the purchase or repair of equipment, photographic or video evidence of abatement or other written records.
Recent events (2)
  • — C (R) $7566
  • — Z (R) $7566

1910.37 B06

Other-than-serious 2 instances 3 exposed
Issued
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.37(b)(6):  Each exit sign was not illuminated to a surface value of at least five foot-candles (54 lux) by a reliable light source and be distinctive in color:  a) 350 South Winding Road DOVER, PA 17315 - The "Exit" sign posted above the designated exit door was non-illuminated in the Cabinet Room, on or about January 7,2025.  b) 350 South Winding Road DOVER, PA 17315 - The "Exit" sign posted above the designated exit door was non-illuminated in the Door Room, on or about January 7,2025.  Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (2)
  • — C (O) $0
  • — Z (O) $0

1910.132 D02

Other-than-serious 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.132(d)(2): The employer did not verify, through a written certification, that the required workplace hazard assessment had been performed:  a) 350 South Winding Road DOVER, PA 17315 - The employer did not complete a Personal Protective Equipment Assessment, exposing employees to workplace hazards, on or about January 7, 2025.  Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (2)
  • — C (O) $0
  • — Z (O) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 347964884.