Safety Incidents OSHA Severe Injury Reports · 2015–2025
2,004,209Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: EXPRESS WASH OPERATIONS, LLC

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of EXPRESS WASH OPERATIONS, LLC in 3365 CENTER ROAD, BRUNSWICK, OH 44212 (NAICS 811192). OSHA activity number 347977985.

Watch Express Wash Operations, LLC — free Get an email when a new federal OSHA severe-injury report for Express Wash Operations, LLC is published. One employer, no account, unsubscribe in one click.
Site address
3365 CENTER ROAD
City
BRUNSWICK
State
OH
ZIP
44212
Mailing
5821 FAIRVIEW ROAD SUITE 400, CHARLOTTE, NC 28209
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
811192
Employees
13
Ownership type
A

2 citations on file for this inspection.

1910.151 C

Serious Gravity 1 1 instance 2 exposed
Issued
Penalty
Initial $6029.00 · Current $3015.00 Reduced
29 CFR 1910.151(c): Where the eyes or body of any person may be exposed to injurious corrosive materials, suitable facilities for quick drenching or flushing of the eyes and body shall be provided within the work area for immediate emergency use.  On or about January 15, 2025, employees adding chemicals to the chemical reservoirs in the chemical/equipment room were exposed to corrosive materials to include but not limited to UF222 - Ultra Presoak 222, and UF260 - Body Shampoo 260; the employer did not ensure to provide a suitable facility for quick drenching or flushing of the eyes within the immediate work area.
Recent events (2)
  • — I (S) $3015
  • — Z (S) $6029

1910.305 G01 IV A

Other-than-serious 1 instance 13 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.305(g)(1)(iv)(A): Unless specifically permitted otherwise in paragraph (g)(1)(ii) of this section, flexible cords and cables may not be used as a substitute for the fixed wiring of a structure.  On or about January 15, 2025, a flexible cord was used in the chemical/equipment room as a substitute for fixed wiring to energize equipment up to 120-volts to include but not limited to the Accu-Pumps Box 1, Box 2, and Box 3.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View EXPRESS WASH OPERATIONS, LLC's full OSHA safety record →