1,224,460Inspections Most recent open 2026-07-13 Last loaded 2026-07-16
Safety Incidents OSHA Severe Injury Reports · 2015–2025

OSHA Inspection: CHIPPEWA FALLS INDUSTRIES LLC

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of CHIPPEWA FALLS INDUSTRIES LLC in N10261 TWIN ANGELS LN, ALMA CENTER, WI 54611 (NAICS 311613). OSHA activity number 347979395.

Watch Chippewa Falls Industries LLC — free Get an email when a new federal OSHA severe-injury report for Chippewa Falls Industries LLC is published. One employer, no account, unsubscribe in one click.
Site address
N10261 TWIN ANGELS LN
City
ALMA CENTER
State
WI
ZIP
54611
Mailing
W11177 RONINGEN ROAD, BLACK RIVER FALLS, WI 54615
Inspection type
Referral (C)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
311613
Employees
6
Ownership type
A

9 citations on file for this inspection.

1910.22 A02

Serious Gravity 1 1 instance 5 exposed
Issued
Abate by
Penalty
Initial $2128.00 · Current $2128.00
29 CFR 1910.22(a)(2): The employer did not ensure that the floor of each workroom was maintained in a clean and, to the extent feasible, in a dry condition; and/or the employer did not ensure that when wet processes were used, drainage was maintained and, to the extent feasible, dry standing places, such as false floors, platforms, and mats were provided:  (a) Building no. N10032; On or about January 9, 2025, and dates prior, two of the floor drains in the workroom floor of the main processing building were clogged with animal hair and by-product, resulting in areas where dirty water had pooled due to improper drainage.
Recent events (1)
  • — Z (S) $2128

1910.28 B06 I

Serious Gravity 5 1 instance 5 exposed
Issued
Abate by
Penalty
Initial $3547.00 · Current $3547.00
29 CFR 1910.28(b)(6)(i): The employer did not ensure that each employee less than 4 feet (1.2 m) above dangerous equipment was protected from falling into or onto the dangerous equipment by a guardrail system or a travel restraint system, unless the equipment is covered or guarded to eliminate the hazard:  (a) Building no. N10032; On or about January 9, 2025, and dates prior, employees were exposed to rotating equipment hazards presented by an open-floor pit with auger that was improperly guarded/barricaded on three sides.
Recent events (1)
  • — Z (S) $3547

1910.37 B06

Serious Gravity 1 4 instances 5 exposed
Issued
Abate by
Penalty
Initial $2128.00 · Current $2128.00
29 CFR 1910.37(b)(6): Each exit sign was not illuminated to a surface value of at least five foot-candles (54 lux) by a reliable light source and distinctive in color:  (a) Building no. N10299; On or about January 15, 2025, and dates prior, the exit sign above the south building exit was not illuminated.   (b) Building no. N10319; On or about January 15, 2025, and dates prior, the exit signs above the north and south building exits were not illuminated.  (c)  Building no. 10329; On or about January 15, 2025, and dates prior, the exit sign above the south building exit was not illuminated.  (d) Building no. N10032; On or about January 9, 2025, and dates prior, the exit sign above the north building exit was not illuminated.
Recent events (1)
  • — Z (S) $2128

1910.101 B

Serious Gravity 5 2 instances 5 exposed
Issued
Abate by
Penalty
Initial $2837.00 · Current $2837.00
29 CFR 1910.101(b): The in-plant handling, storage, and utilization of all compressed gases in cylinders, portable tanks, rail tank cars, or motor vehicle cargo tanks were not in accordance with Compressed Gas Association Pamphlet P-1-1965, which is incorporated by reference as specified in � 1910.6:  (a) Building no. N10329, southeast side of maintenance shop floor; On or about January 15, 2025, and dates prior, the employer did not ensure that the area used to store oxygen-fuel gas welding/cutting cylinders was prominently posted with the names of the gases to be stored, in accordance with the ACG P-1 1965, sec. 3.3.2.   (b) Building no. N10329, southeast side of maintenance shop floor; On or about January 15, 2025, and dates prior, cylinders containing fuel-gas, oxygen, and inert gas were stored in the same location and the employer did not ensure that the cylinders were grouped by different types of gas, and the groups arranged to take into account the gases contained, in accordance with ACG P-1 1965, sec. 3.3.3.
Recent events (1)
  • — Z (S) $2837

1910.253 B02 II

Serious Gravity 5 1 instance 5 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.253(b)(2)(ii): Assigned storage spaces for cylinders were not located away from elevators, stairs, or gangways where cylinders could not be knocked over or damaged by passing or falling objects, or subject to tampering by unauthorized persons:  (a) Building no. N10329, southeast side of maintenance shop floor; On or about January 15, 2025, and dates prior, oxygen-fuel gas welding/cutting cylinders, stored near an interior wall where vehicles were driven nearby and where employees walked and worked within close proximity, were not protected from damage and/or secured to prevent tip-over.
Recent events (1)
  • — Z (S) $0

1910.253 B04 III

Serious Gravity 5 1 instance 5 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.253(b)(4)(iii): Oxygen cylinders in storage were not separated from fuel-gas cylinders or combustible materials (especially oil or grease), a minimum distance of 20 feet (6.1 m) or by a noncombustible barrier at least 5 feet (1.5 m) high having a fire-resistance rating of at least one-half hour:  (a) Building no. N10329, southeast side of maintenance shop floor; On or about January 15, 2025, and dates prior, a compressed oxygen cylinder and dissolved acetylene cylinder, stored near an interior wall, were located right next to each other and were not separated by a fire-resistant barrier.
Recent events (1)
  • — Z (S) $0

1910.141 A05

Serious Gravity 5 1 instance 5 exposed
Issued
Abate by
Penalty
Initial $2837.00 · Current $2837.00
29 CFR 1910.141(a)(5): Every enclosed workplace was not constructed, equipped, and maintained, so far as reasonably practicable, as to prevent the entrance or harborage of rodents, insects, and other vermin; and/or a continuing and effective extermination program was not instituted where their presence is detected:  (a) Building no. N10032; On or about January 15, 2025, and dates prior, the employer did not ensure that the main processing building was constructed and maintained, to the extent feasible, in order to reduce routes of entry for rats and other rodents and/or did not implement a continuing and effective  extermination program to irradicate them.
Recent events (1)
  • — Z (S) $2837

1910.178 L01 I

Serious Gravity 5 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $2837.00 · Current $2837.00
29 CFR  1910.178(l)(1)(i): The employer did not ensure that each powered industrial truck operator is competent to operate a powered industrial truck safely, as demonstrated by the successful completion of the training and evaluation specified in this paragraph (l):  (a) Throughout the establishment; On or about January 9, 2025, and dates prior, employees who operated type LP forklifts, including a Nissan model MUL02A25LV and/or a UniCarriers model MCP 1F2A25LV, were not trained and evaluated on powered industrial truck operation, in accordance with 1910 Subpart N paragraph (l) requirements.
Recent events (1)
  • — Z (S) $2837

1910.254 D09 III

Serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $2837.00 · Current $2837.00
29 CFR 1910.254(d)(9)(iii): Cables with damaged insulation or exposed bare conductors were not replaced:  (a) Building no. N10032; On or about January 9, 2025, a Hobart brand Ironman 230 wire feed welder was used to make repairs to the auger pit and the power cord was damaged near the plug-end.
Recent events (1)
  • — Z (S) $2837