Safety Incidents OSHA Severe Injury Reports · 2015–2025
3,913,242Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: BLAIR STRIP STEEL CO.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of BLAIR STRIP STEEL CO. in 1209 BUTLER AVENUE, NEW CASTLE, PA 16101 (NAICS 331221). OSHA activity number 347981920.

Watch Blair Strip Steel CO. — free Get an email when a new federal OSHA severe-injury report for Blair Strip Steel CO. is published. One employer, no account, unsubscribe in one click.
Site address
1209 BUTLER AVENUE
City
NEW CASTLE
State
PA
ZIP
16101
Mailing
1209 BUTLER AVENUE, NEW CASTLE, PA 16101
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
331221
Employees
50
Ownership type
A

2 citations on file for this inspection.

1910.212 A01

Serious Gravity 5 2 instances 10 exposed
Issued
Abate by
Penalty
Initial $7035.00 · Current $4300.00 Reduced
29 CFR  1910.212(a)(1):One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks:  A) Blair strip Steel Co. on or about January 16, 2025 at the address of 1209 Butler Avenue, New Castle, PA: The rotating coil winders on the Lee Wilson Slitter #38 were not guarded.   B) Blair strip Steel Co. on or about January 16, 2025 at the address of 1209 Butler Avenue, New Castle, PA: The rotating coil winders on the Lee Wilson 24-inch Slitter were not guarded.
Recent events (2)
  • — I (S) $4300
  • — Z (S) $7035

1910.212 A03 II

Serious Gravity 5 1 instance 5 exposed
Issued
Penalty
Initial $7035.00 · Current $4300.00 Reduced
29 CFR  1910.212(a)(3)(ii): Point(s) of operation of machinery were not guarded to prevent employee(s) from having any part of their body in the danger zone(s) during operating cycle(s):   A) Blair strip Steel Co. on or about January 16, 2025 at the address of 1209 Butler Avenue, New Castle, PA: The Lee Wilson shear was not guarded on the infeed and outfeed side of the point of operation (i.e. shearing section).
Recent events (2)
  • — I (S) $4300
  • — Z (S) $7035

View BLAIR STRIP STEEL CO.'s full OSHA safety record →