Safety Incidents OSHA Severe Injury Reports · 2015–2025
2,004,209Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: NYCO PRODUCTS COMPANY

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of NYCO PRODUCTS COMPANY in 5332 DANSHER ROAD, COUNTRYSIDE, IL 60525 (NAICS 325611). OSHA activity number 347982043.

Watch Nyco Products Company — free Get an email when a new federal OSHA severe-injury report for Nyco Products Company is published. One employer, no account, unsubscribe in one click.
Site address
5332 DANSHER ROAD
City
COUNTRYSIDE
State
IL
ZIP
60525
Mailing
5332 DANSHER ROAD, COUNTRYSIDE, IL 60525
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
325611
Employees
49
Ownership type
A

3 citations on file for this inspection.

1910.147 D

Serious Gravity 5 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $6620.00 · Current $3750.00 Reduced
29 CFR 1910.147(d):  The established procedure for the application of energy control (the lockout or tagout procedures) did not cover the actions listed in and was not done in sequence as required by 29 CFR 1910.147(d)(1)-(6):  a.  On or about November 16, 2024, at the Pail Line, an employee was exposed to machine hazards associated with moving parts during the servicing and/or maintenance of a Pacer Series "G" sump pump, ultimately resulting in a partial amputation to left ring fingertip.  The employer failed to implement energy control application steps as the machine was not shut down or turned off to perform the servicing work [per the 1910.147(d)(2) requirements].  As a result, the remaining applicable energy control elements, involving machine isolation [(d)(3)], LOTO device application [(d)(4)], dissipation of residual energy [(d)(5)((i)], and verification of isolation [(d)(6)], were not implemented to protect employees from machine servicing hazards.
Recent events (2)
  • — I (S) $3750
  • — Z (S) $6620

1910.303 B01

Serious Gravity 5 2 instances 6 exposed
Issued
Penalty
Initial $6620.00 · Current $3750.00 Reduced
29 CFR 1910.303(b)(1):  Electrical equipment was not free from recognized hazards that were likely to cause death or serious physical harm to employees.  a.  On or about November 16, 2024, at the Pail Line, employees were required to access a control panel to manually operate the automatic-off-manual toggle switches for the Pacer "G" series sump pumps, thereby being exposing to electrical hazards associated with energized wires.
Recent events (2)
  • — I (S) $3750
  • — Z (S) $6620

1910.147 C06 I

Other-than-serious 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.147(c)(6)(i): The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed.  a.  On or about November 16, 2024, in the facility, the employer did not conduct a periodic inspection of the energy control procedures to ensure that the procedure and requirements of this standard were being followed.  Employees were thereby exposed to the hazards associated with unexpected re-energization of equipment.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View NYCO PRODUCTS COMPANY's full OSHA safety record →