WATERTOWN, CT —
OSHA Inspection: GROUP SEVEN AUTOMOTIVE, LLC
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of GROUP SEVEN AUTOMOTIVE, LLC in 724 STRAITS TURNPIKE, WATERTOWN, CT 06795 (NAICS 441120). OSHA activity number 347994261.
Where did this inspection happen?
- Establishment
- GROUP SEVEN AUTOMOTIVE, LLC
- Site address
- 724 STRAITS TURNPIKE
- City
- WATERTOWN
- State
- CT
- ZIP
- 06795
- Mailing
- 724 STRAITS TURNPIKE, WATERTOWN, CT 06795
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 441120
- Employees
- 16
- Ownership type
- A
Citations
15 citations on file for this inspection.
1910.22 A01
- Issued
- Abate by
- Penalty
- Initial $2837.00 · Current $0.00 Reduced
General-duty citation text
29 CFR 1910.22(a)(1): The employer did not ensure that all places of employment, passageways, storerooms, service rooms, and walking-working surfaces are kept in a clean, orderly, and sanitary condition. Compressor Room. On or about January 23, 2025 the floor of the compressor room was covered with several layers of oil and absorbent material.
Recent events (2)
- — I (S) $0
- — Z (S) $2837
1910.106 H08 III
- Issued
- Abate by
- Penalty
- Initial $4729.00 · Current $0.00 Reduced
1340
General-duty citation text
29 CFR 1910.106(h)(8)(iii): Combustible waste material and residues in a building or operating area were not stored in closed metal waste cans and were not disposed of daily as required by the standard. Repair Bays. On or about January 23, 2025 rags used for the cleanup of flammable and combustible liquids to include gasoline, motor oil, and assorted aerosol cleaners and lubricants were not stored in a closed waste can or disposed of daily.
Recent events (2)
- — I (S) $0
- — Z (S) $4729
1910.157 E03
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.157(e)(3): Portable fire extinguishers were not subjected to an annual maintenance check: Repair Bays. On or about January 23, 2025 three portable fire extinguishers were not subject to an annual maintenance check within the past twelve months.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.132 D01
- Issued
- Abate by
- Penalty
- Initial $5675.00 · Current $2000.00 Reduced
General-duty citation text
29 CFR 1910.132(d)(1): The employer did not assess the workplace to determine if hazards were present, or were likely to be present, which necessitated the use of personal protective equipment: Repair bays. On or about January 23, 2025 the employer did not conduct hazard assessment of the workplace to determine the presence of recognized hazards within the automotive repair industry.
Recent events (2)
- — I (S) $2000
- — Z (S) $5675
1910.132 F01
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.132(f)(1): The employer did not provide training to each employee who is required by this section to use personal protective equipment: Repair Bays. On or about January 23, 2025 the employer did not provide training to employees that were provided with hand protection.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.132 H01
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.132(h)(1): The employer did not provide the personal protective equipment (PPE) used to comply with this part at no cost to employees. Repair Bays. On or about January 23, 2025 the employer did not provide PPE such as eye protection necessary to comply with this part at no cost to their employees.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.215 A02
- Issued
- Abate by
- Penalty
- Initial $3783.00 · Current $1000.00 Reduced
General-duty citation text
29 CFR 1910.215(a)(2): Abrasive wheel(s) used on grinding machinery were not provided with safety guard(s) which covered the spindle end, nut, flange projections: Repair Bays. On or about January 23, 2025 a Bauer 201521E-B 6" Bench Grinder was not equipped with a safety guard that covered the spindle end and nut.
Recent events (2)
- — I (S) $1000
- — Z (S) $3783
1910.215 A04
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.215(a)(4): Grinding machinery was not used with work rest(s) to support offhand grinding work: Repair Bays. On or about January 23, 2025 a Bauer 201521E-B 6" Bench Grinder was not equipped with work rests to support offhand grinding work.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.215 B09
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.215(b)(9): The distance between the abrasive wheel periphery(s) and the adjustable tongue or the end of the safety guard peripheral member at the top exceeded one fourth inch: Repair Bays. On or about January 23, 2025 the distances between the abrasive wheel peripheries and the adjustable tongues at the top of a Bauer 201521E-B 6" Bench Grinder measured approximately one third of an inch.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.305 B02 I
- Issued
- Abate by
- Penalty
- Initial $3783.00 · Current $2000.00 Reduced
General-duty citation text
29 CFR 1910.305(b)(2)(i): Covers of outlet boxes having holes through which flexible cord pendants passed were not provided with bushings designed for the purpose nor did the holes have smooth, well-rounded surfaces on which the cords could bear. Pull boxes, junction boxes, and fittings were not provided with covers approved for the purpose: Repair Bays, photo/ detail area. On or about January 23, 2025: a) Compressor Room. An Ingersoll-Rand 2475 air compressor was not equipped with the manufacturer-supplied control box cover, exposing employees to live conductors when operating the "Off/ Auto" switch. b) Compressor Room. The knockout of a junction box used to supply power to an overhead light was only partially opened and was not equipped with a bushing. c) Photo/ detail area. A junction box was not fitted with a cover. Live conductors extended approximately 12 inches out of the box. d) Photo/ detail area. Four knockouts were missing from a lightswitch.
Recent events (2)
- — I (S) $2000
- — Z (S) $3783
1910.1200 E04
- Issued
- Abate by
- Penalty
- Initial $5675.00 · Current $2000.00 Reduced
General-duty citation text
29 CFR 1910.1200(e)(4): The employer did not make the written hazard communication program available upon request to the Assistant Secretary and the Director in accordance with 29 CFR 1910.1020(e): On or about January 23, 2025 the employer did not make the written hazard communication program available to a designee of the Assistant Secretary upon request.
Recent events (2)
- — I (S) $2000
- — Z (S) $5675
1910.1200 F08
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.1200(f)(8): The employer did not ensure that portable containers into which hazardous chemicals were transferred from labeled containers and which were not intended for the immediate use of the person doing the transfer were properly labeled. Detail/ photo area. On or about January 23, 2025 the employer did not ensure that secondary containers containing various cleaning chemicals were labeled in accordance with 29 CFR 1910.1200(f)(6).
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.1200 G11
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.1200(g)(11): Safety data sheets were not made readily available, upon request, to designated representatives, the Assistant Secretary, and the Director, in accordance with the requirements of 29 CFR 1910.1020(e). On or about January 23, 2025 Safety Data Sheets for the facility's entire chemical inventory were not made readily available to a designee of the Assistant Secretary upon request.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.151 C
- Issued
- Abate by
- Penalty
- Initial $6620.00 · Current $0.00 Reduced
General-duty citation text
29 CFR 1910.151(c): Where employees were exposed to injurious corrosive materials, suitable facilities for quick drenching or flushing of the eyes and body were not provided within the work area for immediate emergency use: East wall of repair bays. On or about January 23, 2025 the employer did not ensure that a suitable eyewash station was provided within the work area for immediate emergency use where employees were exposed to injurious corrosive materials such as battery acid.
Recent events (2)
- — I (S) $0
- — Z (S) $6620
1910.305 G01 IV A
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.305(g)(1)(iv)(A): Flexible cords and/or cables were used as a substitute for the fixed wiring of a structure: Detail/ photo area. On or about January 23, 2025 several 50 foot lengths of 12/3 STJW flexible cord were used as a substitute for fixed wiring to supply power for overhead lighting.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections in this industry (NAICS 441120)
TACOMA, WA—2026-07-15
WA317992061 - SUNNYSET INC
POULSBO, WA—2026-07-14
WA317991772 - LIBERTY BAY AUTO INC
TRACY, CA—2026-06-18
CARVANA, LLC
CHANDLER, AZ—2026-06-16
RFX2026XBM831X0025 - UNITED ACCESS, LLC
TRACY, CA—2026-06-10
MHZ AUTO INC.
More inspections in CT
ENFIELD, CT—2026-07-16
MOMS ENFIELD
DAYVILLE, CT—2026-07-16
HARBOR FREIGHT
NEW BRITAIN, CT—2026-07-14
JANANII, LLC
NEWINGTON, CT—2026-07-14
TRUSS MANUFACTURING INC
NORTH BRANFORD, CT—2026-07-14
NYK STATEWIDE MOLINA CONSTRUCTION LLC
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 347994261.