Safety Incidents OSHA Severe Injury Reports · 2015–2025
2,004,209Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: ROTOR-TECH, INC.

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of ROTOR-TECH, INC. in 10613 STEBBINS CIRCLE, HOUSTON, TX 77043 (NAICS 488190). OSHA activity number 348000787.

Watch Rotor-Tech, INC. — free Get an email when a new federal OSHA severe-injury report for Rotor-Tech, INC. is published. One employer, no account, unsubscribe in one click.
Establishment
ROTOR-TECH, INC.
Site address
10613 STEBBINS CIRCLE
City
HOUSTON
State
TX
ZIP
77043
Mailing
10613 STEBBINS CIRCLE, HOUSTON, TX 77043
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
488190
Employees
15
Ownership type
A

5 citations on file for this inspection.

1910.101 B

Other-than-serious Gravity 10 4 instances 4 exposed
Issued
Abate by
Penalty
Initial $6620.00 · Current $3972.00 Reduced
29 CFR  1910.101(b):The onsite handling, storage, and utilization of all compressed gases in cylinders, portable tanks, rail tank cars, or motor vehicle cargo tanks were not in accordance with Compressed Gas Association Pamphlet P-1-1965, which is incorporated by reference as specified in CFR 1910.6:  On or about January 27, 2025, and times prior thereto, in the main workshop area,  compressed gas cylinders and portable tanks were not stored in accordance with Compressed Gas Association Pamphlet P-1-1965.  a) Unsecured compressed gas cylinder, contents unknown. b) Unsecured propane fuel cylinder for forklift. c) Unsecured propane fuel cylinder for forklift. d) Unsecured 20-pound fuel cylinder for grill or propane fueled appliance.
Recent events (2)
  • — I (O) $3972
  • — Z (S) $6620

1910.134 C01

Other-than-serious Gravity 10 1 instance 4 exposed
Issued
Abate by
Penalty
Initial $6620.00 · Current $3972.00 Reduced
29 CFR  1910.134(c)(1): A written respiratory protection program that included the provisions in 29 CFR 1910.134(c)(1)(i) - (ix) with worksite specific procedures was not established and implemented for required respirator use:  On or about January 27, 2025, and times prior, in the main workshop area, a written respiratory protection program with required worksite-specific procedures and elements for required respirator use was not implemented.
Recent events (2)
  • — I (O) $3972
  • — Z (S) $6620

1910.212 A01

Serious Gravity 10 6 instances 4 exposed
Issued
Abate by
Penalty
Initial $6620.00 · Current $3972.00 Reduced
29 CFR  1910.212(a)(1):One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks:  On or about January 27, 2025, and times prior to, in the main workshop area, the  adequate machine guarding was not used to protect from rotating parts, and high pressure.  a) Summit vertical milling machine not guarded at point of operation b) Craftsman drill press S/N 96080Q0004 not guarded at point of operation c) Craftsman drill press S/N 96083Q0056 not guarded at point of operation d) Craftsman drill press S/N 9608300028 not guarded at point of operation e) Jet grinder S/N 11070736 not guarded at point of operation f) Pressure test station not guarded at point of operation
Recent events (2)
  • — I (S) $3972
  • — Z (S) $6620

1910.303 G01 II

Serious Gravity 10 4 instances 4 exposed
Issued
Abate by
Penalty
Initial $6620.00 · Current $3972.00 Reduced
29 CFR  1910.303(g)(1)(ii):The required working space about electric equipment rated 600 volts, nominal, or less to ground, was used for storage:  On or about January 27, 2025, and times prior to,  in the main workshop, the working area in front of electrical panels were not clear of storage of materials.  a) Blocked electrical panel behind the vertical milling machine b) Blocked electrical panel near the workbench c) Blocked electrical panel near the paint booth d) Blocked electrical panel near the storage area
Recent events (2)
  • — I (S) $3972
  • — Z (S) $6620

1910.29 D01 II

Deleted Other-than-serious 1 instance 4 exposed
Issued
Penalty
Initial $531.00 · Current $0.00 Reduced
29 CFR  1910.29(d)(1)(ii): When the employer used a designated area, the employer did not ensure  that the perimeter of the designated area is delineated with a warning line consisting of a rope, wire, tape, or chain that meets the requirements of paragraphs (d)(2) and (3) of this section.  On or about January 27, 2025, and times prior, in the loading dock area, there was not a designated area with a warning line consisting of a rope, wire, tape, or chain.
Recent events (2)
  • — I (O) $0
  • — Z (O) $531

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 348000787.