Safety Incidents OSHA Severe Injury Reports · 2015–2025
4,113,118Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: EPSCO POWDER AND INDUSTRIAL COATINGS LLC

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of EPSCO POWDER AND INDUSTRIAL COATINGS LLC in 108 WEST 37TH STREET, BOISE, ID 83714 (NAICS 325510). OSHA activity number 348007220.

Watch Epsco Powder AND Industrial Coatings LLC — free Get an email when a new federal OSHA severe-injury report for Epsco Powder AND Industrial Coatings LLC is published. One employer, no account, unsubscribe in one click.
Site address
108 WEST 37TH STREET
City
BOISE
State
ID
ZIP
83714
Mailing
108 WEST 37TH STREET, BOISE, ID 83714
Inspection type
Complaint (B)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
325510
Employees
7
Ownership type
A

16 citations on file for this inspection.

1910.107 B05 I

Serious Gravity 10 2 instances 4 exposed
Issued
Abate by
Penalty
Initial $4965.00 · Current $2483.00 Reduced
29 CFR  1910.107(b)(5)(i): There were no visible gauges, audible alarms or pressure activated devices installed in paint spray booths to indicate or ensure that the required air speed was maintained.  (a) Little Booth: On and prior to January 29, 2025, employees performed spraying activities using 420G-104 One Coat Gray, a Category 3 flammable chemical. The paint booth did not  have a means to ensure flammable vapors were adequately exhausted.   (b) Big Booth: On and prior to January 29, 2025, employees performed spraying activities using 420G-104 One Coat Gray, a Category 3 flammable chemical. The paint booth did not  have a means to ensure flammable vapors were adequately exhausted.
Recent events (2)
  • — I (S) $2482.5
  • — Z (S) $4965

1910.107 B05 IV

Serious Gravity 10 1 instance 4 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR  1910.107(b)(5)(iv): Space within the spray booth on the downstream and upstream sides of filters were not protected with approved automatic sprinklers:  (a) Little Booth: On and prior to January 29, 2025, employees performed spraying activities using 420G-104 One Coat Gray, a Category 3 flammable chemical.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.107 B09

Serious Gravity 10 2 instances 4 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR  1910.107(b)(9): A clear space of not less than 3 feet on all sides was not kept free from storage or combustible construction:  (a) Little Booth: on and prior to January 29, 2025, employees performed spraying activities using 420G-104 One Coat Gray, a Category 3 flammable chemical. Cardboard was stored against the south-west side.    (b) Big Booth: on and prior to January 29, 2025, employees performed spraying activities using 420G-104 One Coat Gray, a Category 3 flammable chemical. Cardboard boxes containing flammable chemical products used during spraying activities were stored against the south-west side.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.107 I04

Serious Gravity 10 2 instances 4 exposed
Issued
Abate by
Penalty
Initial $4965.00 · Current $2482.00 Reduced
29 CFR  1910.107(i)(4): Transformers, powerpacks, control apparatus, and all other electrical portions of the equipment, with the exception of the handgun itself and its connections to the power supply were not located outside of the spraying area or did not otherwise conform to the requirements of paragraph (c) of this section.  (a) Big Booth: On and at times prior to January 29, 2025, employees operated powder coating equipment using flammable chemicals, which was powered by a short three outlet "pigtail"  extension cord connected to another extension cord. Both extension cords were located within the booth.  (b) Big Booth: On and at times prior to January 29, 2025, employees operated powder coating equipment using flammable chemicals, which was powered by a short three outlet "pigtail" extension cord connected to another extension cord. Extension cords were not rated for use in locations containing both deposits of readily ignitable residue and explosive vapor.
Recent events (2)
  • — I (S) $2482
  • — Z (S) $4965

1910.303 B01

Serious Gravity 10 2 instances 5 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR  1910.303(b)(1): Electrical equipment was not free from recognized hazards that were likely to cause death or serious physical harm to employees:  (a) Blasting Booth: On and at times prior to January 29, 2025, employees operated blasting equipment with a power cord that was missing approximately 1 foot of the outer jacket and insulation.  (b) Little Booth: On and at times prior to January 29, 2025, employees used flammable chemicals for spraying activities. The spraying equipment was powered by an extension cord with damaged insulation.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.303 B02

Serious Gravity 10 1 instance 4 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR  1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling:  (a) Big Booth: On and at times prior to January 29, 2025, employees operated powder coating equipment which was powered by a short three outlet "pigtail"  extension cord connected to another extension cord.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.305 G01 IV A

Serious Gravity 10 2 instances 1 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR  1910.305(g)(1)(iv)(A):  Flexible cords and/or cables were used as a substitute for the fixed wiring of a structure:  (a) Blasting Booth: On and at times prior to January 29, 2025, an extension cord supplied power to the shop light mounted on the north-west wall.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.178 L01 I

Serious Gravity 10 1 instance 4 exposed
Issued
Abate by
Penalty
Initial $4965.00 · Current $2482.00 Reduced
29 CFR  1910.178(l)(1)(i): The employer did not ensure that each powered industrial truck operator is competent to operate a powered industrial truck safely, as demonstrated by the successful completion of the training and evaluation specified in this paragraph (l):  (a) On and prior to January 29, 2025, employees operated a Yale, Model GLP060VXNGRE091, S/N B875V10187K forklift to move and support JST frames.
Recent events (2)
  • — I (S) $2482
  • — Z (S) $4965

1910.178 M02

Serious Gravity 10 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR  1910.178(m)(2): Employee(s) stood under or passed under the elevated portion of a powered industrial truck(s):  (a) On and at times prior to January 29, 2025, employees positioned themselves underneath aluminum JST frames supported by the forks of a Yale, Model GLP060VXNGRE091, S/N B875V10187K forklift in order to paint the bottoms.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.303 F02

Serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $4256.00 · Current $2480.00 Reduced
29 CFR 1910.303(f)(2): Each service, feeder, and branch circuit, at its disconnecting means or overcurrent device, was not legibly marked to indicate its purpose, nor located and arranged so the purpose was evident:  (a) Blasting Booth: On and at times prior to January 29, 2025, circuit breakers on the electrical panel were not labeled with what they provide power to. The circuit breakers control the lights, receptacles, and generator.
Recent events (2)
  • — I (S) $2479.5
  • — Z (S) $4256

1910.303 F03

Serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR  1910.303(f)(3): The markings required by paragraphs (f)(1) and (f)(2) of 29 CFR 1910.303 were not sufficiently durable to withstand the environment involved:  (a) Blasting Booth: On and at times prior to January 29, 2025, circuit breakers on the electrical panel were labeled with a permanent marker but could not be identified due to fading. The circuit breakers control the lights, receptacles, and generator.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.303 G01

Serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR  1910.303(g)(1): Sufficient access and working space was not provided and maintained about all electric equipment (operating at 600 volts, nominal, or less to ground) to permit ready and safe operation and maintenance of such equipment:   (a) Blasting Booth: On and at times prior to January 29, 2025, the door of the electrical panel could not be opened as it was blocked by a 6" metal pipe which was part of the permanent structure. The door opened approximately 8 inches before hitting the pipe.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.305 B01 II

Serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR  1910.305(b)(1)(ii): Unused openings in boxes, cabinets, or fittings were not effectively closed:  (a) Blasting Booth: On and at times prior to January 29, 2025, the electrical panel was missing circuit breakers or blanks and the space was covered by duct tape.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.305 G01 IV B

Serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR  1910.305(g)(1)(iv)(B): Flexible cords and cables were run through holes in walls, ceilings, or floors:  (a) Blasting Booth: On and at times prior to January 29, 2025, an extension cord that provided power to a light mounted on the north-west wall was run through a hole in the north wall.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.332 B01

Deleted Serious Gravity 5 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR  1910.332(b)(1): Employees were not trained in and familiar with the safety-related work practices required by 1910.331 through 1910.335 that pertained to their respective job assignments:  (a) On and at times prior to January 29, 2025, employees performed work including accessing the electrical panel of the blasting booth and installing electrical wiring and equipment.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.305 J02 VI

Serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $4256.00 · Current $0.00 Reduced
29 CFR  1910.305(j)(2)(vi): A receptacle installed in a wet location where the product intended to be plugged into it was not to be attended while in use (for example, sprinkler system controllers, landscape lighting, and holiday lights) did not have an enclosure that was weatherproof with the attachment plug cap inserted or removed:  (a) Blasting Booth: On and at times prior to January 29, 2025, an electrical box rated for wet use and installed outside was missing the cover. The box housed an outlet in which an extension cord was continuously plugged connected.
Recent events (2)
  • — I (S) $0
  • — Z (S) $4256

View EPSCO POWDER AND INDUSTRIAL COATINGS LLC's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 348007220.