OSHA Inspection: PRESTIGE SPAS, LLC.

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of PRESTIGE SPAS, LLC. in 2875 MCI DR., PINELLAS PARK, FL 33782 (NAICS 339999). OSHA activity number 348020066.

Watch Prestige Spas, LLC. — free Get an email when a new federal OSHA severe-injury report for Prestige Spas, LLC. is published. One employer, no account, unsubscribe in one click.
Establishment
PRESTIGE SPAS, LLC.
Site address
2875 MCI DR.
City
PINELLAS PARK
State
FL
ZIP
33782
Mailing
2875 MCI DR., PINELLAS PARK, FL 33782
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
339999
Employees
60
Ownership type
A

3 citations on file for this inspection.

1910.212 A01

Other-than-serious Gravity 5 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $9931.00 · Current $5000.00 Reduced
29 CFR  1910.212(a)(1):One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks:  a) At production area, employees engaged in Styrofoam cutting were exposed to amputation hazards, in that the CNC machine , Make: C.R. Onsrud, Model: 241G18, did not have a method of machine guarding to prevent employees from entering any part of their body into the point of operation when the machine's is in operation.
Recent events (3)
  • — R (O) $5000
  • — C (S) $9931
  • — Z (S) $9931

1910.242 B

Other-than-serious Gravity 1 3 instances 5 exposed
Issued
Abate by
Penalty
Initial $4965.00 · Current $2500.00 Reduced
29 CFR  1910.242(b): Compressed air used for cleaning purposes was not reduced to less than 30 p.s.i.:(a)(LOCATION)(IDENTIFY SPECIFIC OPERATION(S) AND/OR CONDITIONS)(DESCRIBE HAZARD(S) WHERE NECESSARY)  a) In the Foam sealing area, compressed air was used for cleaning purposes that was not reduced to an effective pressure of less than 30 psi.  Compressed air hand dispensing wand for cleaning had a dead end measured pressure greater than 45 psi, as observed on or about February 4, 2025.  b) In the CNC machine area, compressed air was used for cleaning purposes that was not reduced to an effective pressure of less than 30 psi.  Compressed air hand dispensing wand for cleaning had a dead end measured pressure of 45 psi, as observed on or about February 4, 2025.  c) In the assembly table adjacent to foam sealing area, compressed air was used for cleaning purposes that was not reduced to an effective pressure of less than 30 psi.  Compressed air hand dispensing wand for cleaning had a dead end measured pressure of 80 psi, as observed on or about February 4, 2025.
Recent events (3)
  • — R (O) $2500
  • — C (S) $4965
  • — Z (S) $4965

1910.305 G01 IV A

Other-than-serious Gravity 5 2 instances 5 exposed
Issued
Abate by
Penalty
Initial $6620.00 · Current $3500.00 Reduced
29 CFR  1910.305(g)(1)(iv)(A):Flexible cords and/or cables were used as a substitute for the fixed wiring of a structure:  a) At the CNC Machine area, employees are exposed to electrical hazards, in that a flexible cord was used to power the computer used at the CNC operation, connected to the battery backup unit.  As observed on or about February 4, 2025.  b) In the foam sealing area, employees are exposed to electrical hazards, in that a flexible cord was used to power a ventilation fan, as observed on or about February 4, 2025.
Recent events (3)
  • — R (O) $3500
  • — C (S) $6620
  • — Z (S) $6620