WILMER, TX —
OSHA Inspection: TRINA SOLAR US MANUFACTURING MODULE 1, LLC
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of TRINA SOLAR US MANUFACTURING MODULE 1, LLC in 1200 SUNRISE ROAD, WILMER, TX 75172 (NAICS 334413). OSHA activity number 348021114.
Where did this inspection happen?
- Establishment
- TRINA SOLAR US MANUFACTURING MODULE 1, LLC
- Site address
- 1200 SUNRISE ROAD
- City
- WILMER
- State
- TX
- ZIP
- 75172
- Mailing
- 1200 SUNRISE ROAD, WILMER, TX 75172
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 334413
- Employees
- 300
- Ownership type
- A
Citations
4 citations on file for this inspection.
1910.147 C06 I
- Issued
- Abate by
- Penalty
- Initial $16550.00 · Current $0.00 Reduced
General-duty citation text
29 CFR 1910.147(c)(6)(i):The employer did not conduct an annual or more frequent inspection of the energy control procedure to ensure that the procedure and requirements of this standard were followed: a) On or about February 4, 2025, and at times prior thereto, in the production area, energy control procedures were not inspected periodically for the Back sheet gluing machine TS23-11-01 serial number SC2475-2-C541-001
Recent events (2)
- — I (S) $0
- — Z (S) $16550
1910.147 C07 I A
- Issued
- Abate by
- Penalty
- Initial $16550.00 · Current $13240.00 Reduced
General-duty citation text
29 CFR 1910.147(c)(7)(i)(A):Authorized employee(s) did not receive training in the recognition of applicable hazardous energy sources, the type and magnitude of the energy available in the workplace, and the methods and means necessary for energy isolation. a) On or about February 4, 2025, and at times prior thereto, in the production area, affected employees who performed the work of authorized employees did not receive authorized employee training on how to perform lock out tag out on
Recent events (2)
- — I (S) $13240
- — Z (S) $16550
1910.147 D04 I
- Issued
- Abate by
- Penalty
- Initial $16550.00 · Current $0.00 Reduced
General-duty citation text
29 CFR 1910.147(d)(4)(i):Lockout or tagout devices were not affixed to each energy isolating device by authorized employees: a) On or about February 4, 2025, and at times prior thereto, on the Back sheet gluing machine TS23-11-01serial number SC2475-2-C541-001, employees were cleaning the nozzles in side the machine without applying locks and/or tags to isolate the energy sources.
Recent events (2)
- — I (S) $0
- — Z (S) $16550
1910.147 C04 II
- Issued
- Abate by
- Penalty
- Initial $16550.00 · Current $0.00 Reduced
General-duty citation text
29 CFR 1910.147(c)(4)(ii):The energy control procedures did not clearly and specifically outline the scope, purpose, authorization, rules, and techniques to be utilized for the control of hazardous energy, including, but not limited to Items of this section. a) On or about February 4, 2025, and at times prior thereto, the employer did not fully document its machine specific lockout tagout procedures for the Back sheet gluing machine TS23-11-01serial number SC2475-2-C541-001.
Recent events (2)
- — I (O) $0
- — Z (S) $16550
More inspections in this industry (NAICS 334413)
ALBANY, NY—2026-06-29
TOKYO ELECTRON
HEMLOCK, MI—2026-06-09
HEMLOCK SEMICONDUCTOR OPERATIONS LLC
HAYWARD, CA—2026-04-30
UTAC
MANASSAS, VA—2026-04-28
MICRON TECHNOLOGY, INC.
IMPERIAL, PA—2026-04-22
INTEGRATED CIRCUIT SYSTEMS
More inspections in TX
SPRING, TX—2026-07-10
DORSTENER WIRE TECH INC.
FORT WORTH, TX—2026-07-10
RC PROFESSIONAL ROOFING OF TEXAS LLC
CYPRESS, TX—2026-07-10
FEDERICO CARVAJAL GARCIA
SAN ANTONIO, TX—2026-07-10
ED LONG'S METAL WORKS
SAN ANTONIO, TX—2026-07-09
WAREHOUSE RACK COMPANY, LP
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 348021114.