Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,214Inspections Most recent open 2026-07-16 Last loaded 2026-07-20

OSHA Inspection: WISCONSIN HARDWOODS LLC

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of WISCONSIN HARDWOODS LLC in 42162 COUNTY HIGHWAY E, MASON, WI 54856 (NAICS 321113). OSHA activity number 348040908.

Watch Wisconsin Hardwoods LLC — free Get an email when a new federal OSHA severe-injury report for Wisconsin Hardwoods LLC is published. One employer, no account, unsubscribe in one click.
Site address
42162 COUNTY HIGHWAY E
City
MASON
State
WI
ZIP
54856
Mailing
42162 COUNTY HIGHWAY E, MASON, WI 54856
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
321113
Employees
23
Ownership type
A

8 citations on file for this inspection.

1910.28 B11 II

Serious Gravity 1 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $2412.00 · Current $1447.00 Reduced
29 CFR 1910.28(b)(11)(ii):29 CFR 1910.28(b)(11)(ii): The employer did not ensure that each flight of stairs having at least 3 treads and at least 4 risers is equipped with stair rail systems and handrails as described in 29 CFR 1910.28 Table D-2-Stairway Handrail Requirements:  (a) Main sawmill building, west end; On or about January 15, 2025, and dates prior, a 42-inch wide stairway, constructed with 17 risers and used to access the parts room, was not equipped with at least one handrail on the enclosed side(s) and a stair rail system on the open side.
Recent events (2)
  • — I (S) $1447.2
  • — Z (S) $2412

1910.147 C05 II D

Serious Gravity 5 2 instances 3 exposed
Issued
Abate by
Penalty
Initial $3215.00 · Current $1929.00 Reduced
29 CFR 1910.147(c)(5)(ii)(D): Lockout devices and tagout devices did not indicate the identity of the employee applying the device(s):  (a) Throughout the main sawmill building; On or about February 11, 2025, and dates prior, lockout devices used during service and maintenance activities did not include the identity of the employees who affixed the devices.
Recent events (2)
  • — I (S) $1929
  • — Z (S) $3215

1910.147 C06 I

Serious Gravity 5 2 instances 3 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.147(c)(6)(i): The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed:  (a) Throughout the main sawmill building; On or about February 11, 2025, and dates prior, the employer did not conduct periodic inspections of the machine-specific energy control procedures on at least an annual basis.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.147 C07 I A

Serious Gravity 5 2 instances 3 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.147(c)(7)(i)(A): Each authorized employee did not receive training in the recognition of applicable hazardous energy sources, the type and magnitude of the energy available in the workplace, and the methods and means necessary for energy isolation and control:   (a) Main sawmill building, Cleereman 54-inch circular head saw; On or about February 11, 2025, and dates prior, servicing and maintenance tasks involving sharpening the saw blade/carbide(s) was performed by an employee who was not properly trained on the methods and means necessary to establish energy isolation and control.   (b) Main sawmill building, Forano 30-foot band resaw; On or about February 11, 2025, and dates prior, servicing and maintenance tasks involving band saw blade changes were performed by employees who were not properly trained on the methods and means necessary to establish energy isolation and control.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.147 D03

Serious Gravity 5 2 instances 3 exposed
Issued
Abate by
Penalty
Initial $3215.00 · Current $1929.00 Reduced
29 CFR  1910.147(d)(3): All energy isolating devices that were needed to control the energy to the machine or equipment were not physically located and operated in such a manner as to isolate the machine or equipment from the energy source(s):  (a) Main sawmill building, Cleereman 54-inch circular head saw; On or about February 11, 2025, and dates prior, an employee who sharpened the saw blade/carbide(s), performed the maintenance task without isolating the equipment's energy sources.    (b) Main sawmill building, Forano 30-foot band resaw; On or about February 11, 2025, and dates prior, employees who changed the band saw blade performed the task without isolating the equipment's energy sources.
Recent events (2)
  • — I (S) $1929
  • — Z (S) $3215

1910.147 D04 I

Serious Gravity 5 2 instances 3 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR  1910.147(d)(4)(i): Lockout or tagout devices were not affixed to each energy isolating device by authorized employees:   (a) Main sawmill building, Cleereman 54-inch circular head saw; On or about February 11, 2025, and dates prior, an employee who sharpened the saw blade/carbide(s), performed the maintenance task without affixing lockout or tagout devices to each energy source isolation device.   (b) Main sawmill building, Forano 30-foot band resaw; On or about February 11, 2025, and dates prior, employees who changed the band saw blade performed the task without affixing lockout or tagout devices to each energy source isolation device.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.242 B

Serious Gravity 1 2 instances 2 exposed
Issued
Abate by
Penalty
Initial $2412.00 · Current $1447.00 Reduced
29 CFR 1910.242(b): Compressed air used for cleaning purposes was not reduced to less than 30 p.s.i.:  (a) Main sawmill building, east end; On or about February 10, 2025, and dates prior, employee(s) cleaned sawdust/debris from equipment using a compressed air blow gun with an approximate airline pressure of up to 85 p.s.i. and the blow gun nozzle was not equipped with side ports or a relief mechanism.   (b) Main sawmill building, west end; On or about February 10, 2025, and dates prior, employees cleaned sawdust from equipment using a compressed air wand with an approximate airline pressure of up to 120 p.s.i. and the wand's nozzle was not equipped with side ports or a relief mechanism.
Recent events (2)
  • — I (S) $1447.2
  • — Z (S) $2412

1904.32 A02

Other-than-serious 1 instance 23 exposed
Issued
Abate by
Penalty
Initial $804.00 · Current $482.00 Reduced
29 CFR 1904.32(a)(2): An annual summary of work-related injuries and illnesses (OSHA Form 300A or equivalent) was not created, certified, or posted:  (a) Throughout the facility; As of February 11, 2025, the employer did not complete an annual summary of work-related injuries and illnesses that occurred during calendar year 2024, using OSHA Form 300A, or equivalent.
Recent events (2)
  • — I (O) $482.4
  • — Z (O) $804

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 348040908.