SHREVEPORT, LA —
OSHA Inspection: SEMPER FI INDUSTRIAL COATINGS
Federal Agency inspection · Safety discipline
At a glance
On , OSHA opened a federal Agency safety inspection of SEMPER FI INDUSTRIAL COATINGS in 6903 PINES ROAD, SHREVEPORT, LA 71129 (NAICS 325510). OSHA activity number 348059478.
Where did this inspection happen?
- Establishment
- SEMPER FI INDUSTRIAL COATINGS
- Site address
- 6903 PINES ROAD
- City
- SHREVEPORT
- State
- LA
- ZIP
- 71129
- Mailing
- 3501 MATTINGLY ROAD 1252 HAILE STREET, BUCKNER, KY 40010
What kind of inspection was it?
- Inspection type
- Federal Agency (M)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Last modified
- Data loaded
Establishment context
- NAICS code
- 325510
- Employees
- 30
- Ownership type
- A
Citations
3 citations on file for this inspection.
1903.19 C01
- Issued
- Abate by
- Penalty
- Initial $930.00 · Current $930.00
General-duty citation text
29 CFR 1903.19(c)(1):Within 10 calendar days after the abatement date, the employer must certify to OSHA (the Agency) that each cited violation has been abated, except as provided in paragraph (c)(2) of this section.
Recent events (1)
- — Z (O) $930
5(a)(1)
- Issued
- Abate by
- Penalty
- Initial $11585.00 · Current $11585.00
General-duty citation text
OSH ACT of 1970 Section (5)(a)(1): The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to struck-by hazards from abrasive blaster tank rupture and/or explosion: a) On or about February 22, 2025, at the LA Water Storage Tank jobsite, employees operated a bulk abrasive blaster at pressures above Maximum Allowable Working Pressure (MAWP) of 125 psi. b) On or about February 22, 2025, at the LA Water Storage Tank jobsite, employees utilized a pressurized bulk abrasive blaster that was missing bolts and hinge pins from the blaster lid closure/hatch.
Recent events (1)
- — Z (S) $11585
1926.306 B03 I
- Issued
- Abate by
- Penalty
- Initial $11585.00 · Current $11585.00
General-duty citation text
29 CFR 1926.306(b)(3)(i): Air receivers were not equipped with an indicating pressure gauge (so located as to be readily visible) and with one or more spring-loaded safety valves: a) On or about February 22, 2025, at the LA Water Storage Tank jobsite, employees utilized a bulk abrasive blaster that was not equipped with a spring-loaded safety valve.
Recent events (1)
- — Z (S) $11585
More inspections in this industry (NAICS 325510)
FRONT ROYAL, VA—2026-07-14
AXALTA COATING SYSTEMS, LLC
HEALDSBURG, CA—2026-07-08
RUPERT GIBBON & SPIDER, INC.
ROCKLEDGE, FL—2026-06-24
RICHARD'S PAINT MANUFACTURING CO
ROCHESTER, PA—2026-06-18
THE SHERWIN-WILLIAMS COMPANY
AUBURN, CA—2026-06-15
PRESERVA PRODUCTS LTD
More inspections in LA
LAFAYETTE, LA—2026-07-15
GULLEY'S WELDING & STEEL ERECTORS, INC.
LAFAYETTE, LA—2026-07-15
ACORREA COMPANY, LLC
LAFAYETTE, LA—2026-07-14
GULF COAST WOODWORK, L.L.C.
BELLE ROSE, LA—2026-07-14
OXYCHEM
AMELIA, LA—2026-07-10
CONRAD SHIPYARD, LLC
Source