2,004,209Inspections Most recent open 2026-07-13 Last loaded 2026-07-17
Safety Incidents OSHA Severe Injury Reports · 2015–2025

OSHA Inspection: LUEDTKE ELECTRIC INC

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of LUEDTKE ELECTRIC INC in 1337 N TAYLOR DR, SHEBOYGAN, WI 53081 (NAICS 561790). OSHA activity number 348061383.

Watch Luedtke Electric INC — free Get an email when a new federal OSHA severe-injury report for Luedtke Electric INC is published. One employer, no account, unsubscribe in one click.
Site address
1337 N TAYLOR DR
City
SHEBOYGAN
State
WI
ZIP
53081
Mailing
214 NORTH 10TH STREET, OOSTBURG, WI 53070
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
561790
Employees
12
Ownership type
A

4 citations on file for this inspection.

1910.67 C02 V

Deleted Serious Gravity 10 1 instance 1 exposed
Issued
Penalty
Initial $6620.00 · Current $0.00 Reduced
29 CFR  1910.67(c)(2)(v):  Extensible and articulating boom platforms.  A personal fall arrest or travel restraint system that meets the requirements in 29 CFR part 1910, subpart I, shall be worn and attached to the boom or basket when working from an aerial lift.  On or about February 25, 2025, at 1337 N Taylor Drive in Sheboygan, Wisconsin, an employee was exposed to a fall hazard working from an aerial lift work platform 17 feet above surface level without using required personal fall protection equipment.
Recent events (2)
  • — I (S) $0
  • — Z (S) $6620

1910.30 A02

Serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $3972.00
29 CFR 1910.30(a)(2): The employer must ensure that each employee is trained by a qualified person.  On or about February 25, 2025, at 1337 N Taylor Drive in Sheboygan, Wisconsin, the employer did not provide required fall protection safety training for an employee who was working at heights greater than six feet.
Recent events (2)
  • — I (S) $3972
  • — Z (S) $0

1910.67 C02 II

Serious Gravity 5 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $5675.00 · Current $3405.00 Reduced
29 CFR  1910.67(c)(2)(ii):  Extensible and articulating boom platforms.  Only trained persons shall operate an aerial lift.  On or about February 25, 2025, at 1337 N Taylor Drive in Sheboygan, Wisconsin, the employer did not ensure the employees using a Haulotte 6543A Articulated Telescope Boom Lift had received required operator safety training.  An employee was working from the platform without required personal fall protection equipment, the lift was positioned with front hitch in an active driveway, and all four outriggers were not on a solid surface.
Recent events (2)
  • — I (S) $3405
  • — Z (S) $5675

1910.67 C02 VII

Serious Gravity 5 1 instance 1 exposed
Issued
Penalty
Initial $0.00 · Current $0.00
29 CFR  1910.67(c)(2)(vii):  Extensible and articulating boom platforms.  The brakes shall be set and outriggers, when used, shall be positioned on pads or a solid surface.  On or about February 25, 2025, at 1337 N Taylor Drive in Sheboygan, Wisconsin, an employee was exposed to a fall hazard working from an aerial lift platform 17 feet above surface level without all four outriggers set-up on a solid surface.  One outrigger was on grassy surface.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 348061383.