Safety Incidents OSHA Severe Injury Reports · 2015–2025
4,113,118Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: JUAN LOPEZ ROOFING

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of JUAN LOPEZ ROOFING in 10083 N. TWISTED OAK DR. @ HWY 146, BAYTOWN, TX 77523 (NAICS 238160). OSHA activity number 348062985.

Watch Juan Lopez Roofing — free Get an email when a new federal OSHA severe-injury report for Juan Lopez Roofing is published. One employer, no account, unsubscribe in one click.
Establishment
JUAN LOPEZ ROOFING
Site address
10083 N. TWISTED OAK DR. @ HWY 146
City
BAYTOWN
State
TX
ZIP
77523
Mailing
10500 SKYRIDGE DR, CONROE, TX 77385
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238160
Employees
3
Ownership type
A

2 citations on file for this inspection.

1926.501 B10

Serious Gravity 5 1 instance 2 exposed
Issued
Penalty
Initial $3547.00 · Current $2128.00 Reduced
29 CFR  1926.501(b)(10): Each employee engaged in roofing activities on low-slope roofs, with unprotected sides and edges 6 feet (1.8 m) or more above lower levels, was not protected from falling by guardrail systems, safety net systems, personal fall arrest systems:   a) On or about February 25, 2025, where employees were working on a roof greater than 6 feet high installing a roofing system without a fall protection system.
Recent events (2)
  • — I (S) $2128.2
  • — Z (S) $3547

1926.1053 B01

Serious Gravity 5 1 instance 2 exposed
Issued
Penalty
Initial $3547.00 · Current $2128.00 Reduced
29 CFR  1926.1053(b)(1):Where portable ladders were used for access to an upper landing surface and the ladder's length allows, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface being accessed:  a) On or about February 25, 2025 employees at the south side of a new construction retail building the ladder employees used to access the roof to install roofing material was not extended 3 feet above the upper landing edge.
Recent events (2)
  • — I (S) $2128.2
  • — Z (S) $3547

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 348062985.