Safety Incidents OSHA Severe Injury Reports · 2015–2025
4,113,118Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: KAIZEN AUTO CARE, LLC

Complaint inspection · Health discipline

On , OSHA opened a complaint health inspection of KAIZEN AUTO CARE, LLC in 109 WEST WALNUT STREET, BRIGHTON, CO 80601 (NAICS 811111). OSHA activity number 348076548.

Watch Kaizen Auto Care, LLC — free Get an email when a new federal OSHA severe-injury report for Kaizen Auto Care, LLC is published. One employer, no account, unsubscribe in one click.
Site address
109 WEST WALNUT STREET
City
BRIGHTON
State
CO
ZIP
80601
Mailing
1405 N HAYDEN ROAD, SCOTTSDALE, AZ 85257
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
811111
Employees
10
Ownership type
A

4 citations on file for this inspection.

1910.106 D04 IV

Other-than-serious Gravity 10 2 instances 10 exposed
Issued
Abate by
Penalty
Initial $16550.00 · Current $9930.00 Reduced
29 CFR  1910.106(d)(4)(iv): Every inside storage room was not provided with either a gravity or a mechanical exhaust ventilation system. Such system was not designed to provide for a complete change of air within the room at least six times per hour. A mechanical exhaust system was not controlled by a switch located outside of the door. The ventilating equipment and any lighting fixtures were not operated by the same switch. A pilot light was not installed adjacent to the switch when Category 1 or 2 flammable liquids, or Category 3 flammable liquids with a flashpoint below 100 �F (37.8 �C), were dispensed within the room. Where gravity ventilation was provided, the fresh air intake, as well as the exhaust outlet from the room, were not on the exterior of the building in which the room was located:  a) Paint Mixing Room: On or about March 3, 2025, employees were exposed to respiratory hazards where the ventilation system to the paint mixing room, where Category 2 flammable paints including but not limited to Dynamic Clearcoat and SPECTRA-PRIME Low VOC Primer (Part A) Black were stored, was not functional.  b) Paint Mixing Room: On or about March 3, 2025, employees were exposed to exposed to fire hazards where the ventilating equipment and lights in the paint mixing room, where Category 2 flammable paints including but not limited to Dynamic Clearcoat and SPECTRA-PRIME Low VOC Primer (Part A) Black were stored, were not operated by the same switch. Two separate switches turned on either the lights or the ventilation system.
Recent events (2)
  • — I (O) $9930
  • — Z (S) $16550

1910.107 G02

Deleted Serious Gravity 5 1 instance 4 exposed
Issued
Penalty
Initial $9457.00 · Current $0.00 Reduced
29 CFR  1910.107(g)(2): All spraying areas were not kept as free from the accumulation of deposits of combustible residues as practical, with cleaning conducted daily if necessary:  a) Garage: On or about March 3, 2025, employee were exposed to respiratory hazards where deposits from paints used in the spray guns, including but not limited to Dynamic Clearcoat and SPECTRA-PRIME Low VOC Primer (Part A) Black, were allowed to accumulate in the spray gun cleaning stations.
Recent events (2)
  • — I (S) $0
  • — Z (S) $9457

1910.134 E01

Serious Gravity 5 1 instance 4 exposed
Issued
Penalty
Initial $9457.00 · Current $5674.00 Reduced
29 CFR  1910.134(e)(1): The employer did not provide a medical evaluation to determine the employee's ability to use a respirator, before the employee was fit tested or required to use the respirator in the workplace:  a) Garage: On or about March 3, 2025, the employer did not provide medical evaluations to employees required to wear 3M 5300 or 6300 half face respirators that were spray painting. Employees were exposed to inhalation hazards while working with paints which contain titanium dioxide, n-butyl acetate, and acetone.
Recent events (2)
  • — I (S) $5674.2
  • — Z (S) $9457

1910.134 F02

Serious Gravity 5 1 instance 4 exposed
Issued
Penalty
Initial $0.00 · Current $0.00
29 CFR  1910.134(f)(2):Employee(s) using tight-fitting facepiece respirators were not fit tested prior to initial use of the respirator:   a) Garage: On or about March 3, 2025, the employer did not provide fit testing for tight-fitting respirators to employees required to wear 3M 5300 or 6300 respirators, exposing employees to respiratory hazards while spray painting.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 348076548.