Safety Incidents OSHA Severe Injury Reports · 2015–2025
4,113,118Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: SAS METAL FABRICATIONS CORP.

Complaint inspection · Health discipline

On , OSHA opened a complaint health inspection of SAS METAL FABRICATIONS CORP. in 55 S MACQUESTEN PKWY, MOUNT VERNON, NY 10550 (NAICS 332999). OSHA activity number 348080110.

Watch SAS Metal Fabrications Corp. — free Get an email when a new federal OSHA severe-injury report for SAS Metal Fabrications Corp. is published. One employer, no account, unsubscribe in one click.
Site address
55 S MACQUESTEN PKWY
City
MOUNT VERNON
State
NY
ZIP
10550
Mailing
55 S MACQUESTEN PKWY, MOUNT VERNON, NY 10550
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332999
Employees
5
Ownership type
A

5 citations on file for this inspection.

1910.1200 E01

Serious Gravity 1 1 instance 3 exposed
Issued
Penalty
Initial $1809.00 · Current $1809.00
29 CFR  1910.1200(e)(1): Employer had not developed or implemented a written hazard communication program that included the requirements outlined in 29 CFR 1910.1200(e)(1)(i) and (e)(1)(ii):   Location: 55 South McQuesten Parkway, Mt. Vernon, NY  a) On or about March 4, 2025, the employer did not develop or implement a written hazard communication program for employees who use chemicals such as, but not limited to Dykem Aerosol Remover & Prep, which contains acetone, ethanol and isopropanol while performing metal fabrication.  NOTE: Because abatement of this violation is already documented in the case file, the employer need not submit certification nor documentation of abatement of this violation as normally required by 29 CFR 1903.19.
Recent events (1)
  • — Z (S) $1809

1910.1200 G08

Serious Gravity 1 1 instance 3 exposed
Issued
Penalty
Initial $0.00 · Current $0.00
29 CFR  1910.1200(g)(8): The employer did not maintain in the workplace copies of the required safety data sheets for each hazardous chemical:  Location: 55 South McQuesten Parkway, Mt. Vernon, NY  a) On or about March 4, 2025, the employer did not maintain in the workplace copies of the required safety data sheets for employees who use chemicals such as, but not limited to Dykem Aerosol Remover & Prep, which contains acetone, ethanol and isopropanol while performing metal fabrication.  NOTE: Because abatement of this violation is already documented in the case file, the employer need not submit certification nor documentation of abatement of this violation as normally required by 29 CFR 1903.19.
Recent events (1)
  • — Z (S) $0

1910.1200 H01

Serious Gravity 1 1 instance 3 exposed
Issued
Penalty
Initial $0.00 · Current $0.00
29 CFR  1910.1200(h)(1): Employees were not provided effective information and training on hazardous chemicals in their work area at the time of their initial assignment and whenever a new hazard that the employees had not been previously trained about was introduced into their work area:  Location: 55 South McQuesten Parkway, Mt. Vernon, NY  a) On or about March 4, 2025, the employer did not provide effective information and training on hazardous chemicals in the work area for employees who use chemicals such as, but not limited to Dykem Aerosol Remover & Prep, which contains acetone, ethanol and isopropanol while performing metal fabrication.  NOTE: Because abatement of this violation is already documented in the case file, the employer need not submit certification nor documentation of abatement of this violation as normally required by 29 CFR 1903.19.
Recent events (1)
  • — Z (S) $0

1910.134 E01

Other-than-serious 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR  1910.134(e)(1): The employer did not provide a medical evaluation to determine the employee's ability to use a respirator before the employee used the respirator in the workplace:  Location: Welding area of shop at 55 South McQuesten Parkway, Mt. Vernon, NY  a) On or about March 19, 2025, the employer did not provide a medical evaluation to determine the employee's ability to use a respirator before the employee voluntarily wore a half-face elastomeric while welding.  NOTE: The employer is required to submit abatement certification for this item in accordance with 29 CFR 1903.19.
Recent events (1)
  • — Z (O) $0

1910.134 K06

Other-than-serious 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR  1910.134(k)(6): The employer did not provide the basic advisory information on respirators, as presented in Appendix D of 29 CFR 1910.134, in written or oral format to employees who wear respirators when such use was not required by the employer:  Location: 55 S Macquesten Pkwy, Mt Vernon, NY   a) On or about March 19, 2025, the employer did not provide the basic advisory information on respirators, as presented in Appendix D of 29 CFR 1910.134 to an employee who voluntarily wore a half-face elastomeric respirator while welding.   NOTE: The employer is required to submit abatement certification for this item in accordance with 29 CFR 1903.19.
Recent events (1)
  • — Z (O) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 348080110.