Safety Incidents OSHA Severe Injury Reports · 2015–2025
4,113,118Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: JAGUAR DRYWALL LLC

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of JAGUAR DRYWALL LLC in 387 CHIPPEWA MALL DRIVE (BUILDING 2), CHIPPEWA FALLS, WI 54729 (NAICS 238130). OSHA activity number 348128190.

Watch Jaguar Drywall LLC — free Get an email when a new federal OSHA severe-injury report for Jaguar Drywall LLC is published. One employer, no account, unsubscribe in one click.
Establishment
JAGUAR DRYWALL LLC
Site address
387 CHIPPEWA MALL DRIVE (BUILDING 2)
City
CHIPPEWA FALLS
State
WI
ZIP
54729
Mailing
7897 FIRWOOD WAY NE, FRIDLEY, MN 55432
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Last modified
Data loaded
NAICS code
238130
Employees
6
Ownership type
A

6 citations on file for this inspection.

1926.20 B02

Serious Gravity 5 1 instance 6 exposed
Issued
Abate by
Penalty
Initial $2837.00 · Current $1419.00 Reduced
29 CFR 1926.20(b)(2): The employer did not initiate and maintain programs which provided for frequent and regular inspections of the job site, materials and equipment to be made by a competent person(s):  (a) Residential structure, third floor; On or about March 21, 2025, the employer did not conduct frequent and regular inspections of the job site to identify and correct hazards associated with falls, portable ladder use, and eye protection.
Recent events (2)
  • — I (S) $1418.5
  • — Z (S) $2837

1926.102 A01

Serious Gravity 5 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.102(a)(1):  The employer shall ensure that each affected employee uses appropriate eye or face protection when exposed to eye or face hazards from flying particles, molten metal, liquid chemicals, acids or caustic liquids, chemical gases or vapors, or potentially injurious light radiation:  (a) Residential structure, third floor; On or about March 21, 2025, employees were operating pneumatic nail gun(s) without the use of eye protection.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.501 B13

Serious Gravity 10 1 instance 3 exposed
Issued
Penalty
Initial $4965.00 · Current $2483.00 Reduced
29 CFR 1926.501(b)(13):  Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501(b):   (a) Residential structure, third floor; On or about March 21, 2025, one or more methods of fall protection was not in place while workers performed framing activities near the edge of the floor at a height approximately 24 feet above ground level.
Recent events (2)
  • — I (S) $2482.5
  • — Z (S) $4965

1926.503 A01

Serious Gravity 10 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.503(a)(1): The employer did not provide a training program for each employee potentially exposed to fall hazards to enable each employee to recognize the hazards of falling and the procedures to be followed in order to minimize these hazards:   (a) Residential structure, third floor; On or about March 21, 2025, employees exposed to fall hazards were not adequately trained to recognize fall hazards and/or the procedures to be followed to minimize fall hazards.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.1053 B01

Serious Gravity 5 2 instances 6 exposed
Issued
Penalty
Initial $3547.00 · Current $1774.00 Reduced
29 CFR 1926.1053(b)(1): Where portable ladders were used for access to an upper landing surface and the ladder's length allows, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface being accessed:  (a) Residential structure, southwest corner; On or about March 21, 2025, a Keller KPro KMT-22 21-foot multi-position ladder placed at ground level and used as an extension ladder by employees to access the second floor, was not adjusted to allow for the side rails to extend at least 3 feet above the landing surface.  (b) Residential structure, southeast exterior stair section; On or about March 21, 2025, an extension ladder placed at the second-floor level and used by employees to access the third floor, was not adjusted to allow for the side rails to extend at least 3 feet above the landing surface.
Recent events (2)
  • — I (S) $1773.5
  • — Z (S) $3547

1926.1060 A

Serious Gravity 5 2 instances 6 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.1060(a): The employer did not provide a training program for each employee using ladders and stairways, as necessary, which would enable each employee to recognize hazards related to ladders and stairways and train each employee in the procedures to be followed to minimize these hazards:  (a) Residential structure, various locations; On or about March 21, 2025, training was not provided to inform employees how to properly set up, use, and inspect extension ladders before they were used to access elevated work areas as part of framing activities.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 348128190.