Safety Incidents OSHA Severe Injury Reports · 2015–2025
4,113,118Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: JERYCO ROOFING, LLC

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of JERYCO ROOFING, LLC in 4517 AJO WALK SW, ATLANTA, GA 30331 (NAICS 238160). OSHA activity number 348177478.

Watch Jeryco Roofing, LLC — free Get an email when a new federal OSHA severe-injury report for Jeryco Roofing, LLC is published. One employer, no account, unsubscribe in one click.
Establishment
JERYCO ROOFING, LLC
Site address
4517 AJO WALK SW
City
ATLANTA
State
GA
ZIP
30331
Mailing
79 LILLIAN CIR, STOCKBRIDGE, GA 30281
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238160
Employees
5
Ownership type
A

3 citations on file for this inspection.

1926.102 A01

Serious Gravity 1 1 instance 2 exposed
Issued
Penalty
Initial $2128.00 · Current $1277.00 Reduced
29 CFR  1926.102(a)(1): Eye and face protective equipment were not used when machines or operations presented potential eye or face injury:  a) Residential home at The Cascade Ridge Subdivision, 4517 Ajo Walk SW, Atlanta, GA 30331, Front Roof: On or about 04/11/2025, the employer exposed two employees to struck-by hazard while operating pneumatic nail guns, in that protective eyewear was not provided to employees engaged in roofing activities operating these tools at 120 PSI.
Recent events (2)
  • — I (S) $1276.8
  • — Z (S) $2128

1926.501 B13

Serious Gravity 5 1 instance 2 exposed
Issued
Penalty
Initial $2837.00 · Current $1702.00 Reduced
29 CFR  1926.501(b)(13):Each employee engaged in residential construction activities 6 feet (1.8 m)  or more above lower levels was not protected by guardrail systems, safety net systems, personal fall arrest systems, or an alternative fall protection measure under another provision of paragraph 1926.501(b), nor did the employer demonstrate that it is infeasible or creates a greater hazard to use these systems and develop and implement a fall protection plan which meets the requirements of paragraph (k) of section 1926.502:  a) Residential home at The Cascade Ridge Subdivision, 4517 Ajo Walk SW, Atlanta, GA 30331, Front Roof: On or about 04/11/2025, the employer exposed employees to fall hazards while working on a 10/12 pitched roof with an eave height of approximately 22-feet, 9-inches to the lower ground level, in that a fall protection system was not provided while the employee was engaged in roofing activities.
Recent events (2)
  • — I (S) $1702.2
  • — Z (S) $2837

1926.1053 B01

Serious Gravity 5 1 instance 2 exposed
Issued
Penalty
Initial $2837.00 · Current $1702.00 Reduced
29 CFR  1926.1053(b)(1):Where portable ladders were used for access to an upper landing surface and the ladder's length allows, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface being accessed:  a)  Residential home at The Cascade Ridge Subdivision, 4517 Ajo Walk SW, Atlanta, GA 30331, Front Roof: On or about 04/11/2025, and at times prior, the employer exposed three employees to fall hazards from an eave height of approximately 10- feet, 2-inches to the lower level, in that the ladder side rails of the extension ladder did not extend at least 3-feet past the roof landing to allow for safe access on and off the roof.
Recent events (2)
  • — I (S) $1702.2
  • — Z (S) $2837

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 348177478.