TAMPA, FL —
OSHA Inspection: DESIGN LOFT TAMPA
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of DESIGN LOFT TAMPA in 9208 PALM RIVER ROAD, TAMPA, FL 33619 (NAICS 493110). OSHA activity number 348183971.
Where did this inspection happen?
- Establishment
- DESIGN LOFT TAMPA
- Site address
- 9208 PALM RIVER ROAD
- City
- TAMPA
- State
- FL
- ZIP
- 33619
- Mailing
- 9208 PALM RIVER RD #302B, TAMPA, FL 33619
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Last modified
- Data loaded
Establishment context
- NAICS code
- 493110
- Employees
- 5
- Ownership type
- A
Citations
3 citations on file for this inspection.
1910.37 A03
- Issued
- Abate by
- Penalty
- Initial $4965.00 · Current $4965.00
General-duty citation text
29 CFR 1910.37(a)(3): Exit route(s) were not kept free and unobstructed: (a) In the warehouse area at 9208 Palm River Road Tampa, FL 33619; On or about April 16, 2025 the employer exposed employees to entrapment hazards, in that, the path of egress was obstructed by shipping product. (b) In the warehouse area at 9208 Palm River Road Tampa, FL 33619; On or about April 16, 2025 the employer exposed employees to entrapment hazards, in that, the access to the exit door was obstructed by shipping product, a ladder and trash can.
Recent events (1)
- — Z (S) $4965
1910.157 C01
- Issued
- Abate by
- Penalty
- Initial $3547.00 · Current $3547.00
General-duty citation text
29 CFR 1910.157(c)(1): Portable fire extinguishers were not mounted, located and identified so that they were readily accessible without subjecting the employees to injuries: a) In the warehouse area at 9208 Palm River Road Tampa, FL 33619; On or about April 16, 2025, the employer exposed employees to smoke, fire, and entrapment hazards, in that the employer did not ensure the fire extinguisher in the warehouse area was unobstructed, mounted and identified.
Recent events (1)
- — Z (S) $3547
1910.303 G01 II
- Issued
- Abate by
- Penalty
- Initial $2837.00 · Current $2837.00
General-duty citation text
29 CFR 1910.303(g)(1)(ii): The required working space about electric equipment rated 600 volts, nominal, or less to ground, was used for storage: (a) In the warehouse area at 9208 Palm River Road Tampa, FL 33619; On or about April 16, 2025, metal racks, and shipping materials were stored in the working space around the electrical panels.
Recent events (1)
- — Z (S) $2837
More inspections in this industry (NAICS 493110)
PORTSMOUTH, VA—2026-07-15
DACS INC
WEST CHESTER, OH—2026-07-14
CRESCENT PARK CORPORATION
WEYMOUTH, MA—2026-07-14
SPEEDX
DUNDALK, MD—2026-07-09
WILLIAMS SCOTSMAN, INC.
ROCK HILL, SC—2026-07-08
77566 - WEST MARINE INC
More inspections in FL
MARIANNA, FL—2026-07-16
BRANNON BROTHERS CONSTRUCTION, LLC
LAKELAND, FL—2026-07-16
SOUTHERN MILLING & LUMBER, INC.
OAKLAND PARK, FL—2026-07-16
PKB CABINETRY
LAKELAND, FL—2026-07-16
ELIJAH WHOLESALE, LLC.
TAMPA, FL—2026-07-16
VALENCIA WHOLESALE, INC.
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 348183971.