NORTHBROOK, IL —
OSHA Inspection: CARCHIS ROOFING & CONSTRUCTION INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of CARCHIS ROOFING & CONSTRUCTION INC. in 2532 JASPER CT, NORTHBROOK, IL 60062 (NAICS 238160). OSHA activity number 348187139.
Where did this inspection happen?
- Establishment
- CARCHIS ROOFING & CONSTRUCTION INC.
- Site address
- 2532 JASPER CT
- City
- NORTHBROOK
- State
- IL
- ZIP
- 60062
- Mailing
- 4709 W FULTON ST, APT 2, CHICAGO, IL 60644
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238160
- Employees
- 13
- Ownership type
- A
Citations
7 citations on file for this inspection.
1926.451 E01
- Issued
- Penalty
- Initial $2838.00 · Current $2000.00 Reduced
General-duty citation text
29 CFR 1926.451(e)(1): Safe access was not provided to scaffold platforms when the platforms were more than 2 feet above or below the point of access: a) On April 16, 2025, employees were exposed to a fall hazard of approximately 11.4 feet while accessing a ladder jack scaffold. No abatement certification or documentation is required for this item.
Recent events (2)
- — I (S) $2000
- — Z (S) $2838
1926.451 G01 I
- Issued
- Penalty
- Initial $3972.00 · Current $3000.00 Reduced
General-duty citation text
29 CFR 1926.451(g)(1)(i): Each employee on a boatswains' chair, catenary scaffold, float scaffold, needle beam scaffold, or ladder jack scaffold was not protected by a personal fall arrest system: a) On April 16, 2025, employees working from a ladder jack scaffold were exposed to a fall hazard of approximately 11.4 feet. No abatement certification or documentation is required for this item.
Recent events (2)
- — I (S) $3000
- — Z (S) $3972
1926.501 B13
- Issued
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): a) On April 16, 2025, employees performing roofing work were exposed to fall hazards of approximately 22.6 feet. No abatement certification or documentation is required for this item.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.502 D06 I
- Issued
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1926.502(d)(6)(i): Snaphooks were engaged directly to webbing, rope or wire rope: a) On April 16, 2025, snaphooks were connected to the nylon webbing of body harnesses used for fall protection on pitched roof surfaces. b) On April 16, 2025, snaphooks were connected to the nylon webbing of the lanyard they were connected to. No abatement certification or documentation is required for this item.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.502 D15
- Issued
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1926.502(d)(15): Anchorages used for attachment of personal fall arrest equipment were not independent of any anchorage being used to support or suspend platforms and/or were not capable of supporting at least 5,000 pounds (22.2 kN) per employee: a) On April 16, 2025, anchorages being used for attachment of personal fall arrest equipment were not installed so that they would be capable of supporting at least 5,000 pounds per employee attached. b) On April 16, 2025, anchorages designed for attachment of a single life line were being used to support multiple life lines. No abatement certification or documentation is required for this item.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.502 D17
- Issued
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1926.502(d)(17): The attachment point of the body harness was not located in the center of the wearer's back near shoulder level, or above the wearer's head: a) On April 16, 2025, the front nylon straps of body harnesses were used as attachment points for fall protection on pitched roof surfaces. No abatement certification or documentation is required for this item.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.502 D21
- Issued
- Penalty
- Initial $3972.00 · Current $3000.00 Reduced
General-duty citation text
29 CFR 1926.502(d)(21):Personal fall arrest systems were not inspected prior to each use for wear, damage and other deterioration, and defective components were not removed from service: a) On or about April 16, 2025, a lifeline and lifeline shock-pack used as part of a fall protection system was defective (i.e, torn) and not removed from service. No abatement certification or documentation is required for this item.
Recent events (2)
- — I (S) $3000
- — Z (S) $3972
More inspections in this industry (NAICS 238160)
FAIRVIEW, TN—2026-07-16
MARVIN PINERA
CARSON CITY, NV—2026-07-16
UNKNOWN/INVALID ESTABLISHMENT
BANNOCKBURN, IL—2026-07-16
ROOFING H.P. LLC
LOXLEY, AL—2026-07-16
CARLOS CHE
BALTIMORE, MD—2026-07-16
VAL CONSTRUCTION INC
More inspections in IL
DEERFIELD, IL—2026-07-16
JOHN BURNS CONSTRUCTION COMPANY, LLC
BANNOCKBURN, IL—2026-07-16
BUILDER SERVICES GROUP, INC. DBA CJ INSULATION
BANNOCKBURN, IL—2026-07-16
ROOFING H.P. LLC
HIGHLAND PARK, IL—2026-07-16
UNITED PLUMBING AND DRAIN, INC.
FRANKLIN PARK, IL—2026-07-16
B & M PLASTIC INC.
Source