NORTH PALM BEACH, FL —
OSHA Inspection: CRE CONSTRUCTION LLC
Follow-up inspection · Safety discipline
At a glance
On , OSHA opened a follow-up safety inspection of CRE CONSTRUCTION LLC in 101 DORY RD, NORTH PALM BEACH, FL 33408 (NAICS 236118). OSHA activity number 348191503.
Where did this inspection happen?
- Establishment
- CRE CONSTRUCTION LLC
- Site address
- 101 DORY RD
- City
- NORTH PALM BEACH
- State
- FL
- ZIP
- 33408
- Mailing
- 548 MARLIN RD, NORTH PALM BEACH, FL 33408
What kind of inspection was it?
- Inspection type
- Follow-up (F)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Last modified
- Data loaded
Establishment context
- NAICS code
- 236118
- Employees
- 1
- Ownership type
- A
Citations
3 citations on file for this inspection.
1926.451 B01
- Issued
- Penalty
- Initial $3121.00 · Current $1561.00 Reduced
General-duty citation text
29 CFR 1926.451(b)(1):Each platform on all working levels of scaffolds was not fully planked or decked between the front uprights and the guardrail supports as specified in paragraphs 1926.451(b)(1)(i)-(ii): On or about 4/18/2025, at the jobsite located at 101 Dory Rd, North Palm Beach, FL 33408, employees were exposed to a 6.7-foot fall hazard while working from a scaffold that was not fully planked.
Recent events (2)
- — I (S) $1560.5
- — Z (S) $3121
1926.451 C02 I
- Issued
- Penalty
- Initial $3121.00 · Current $1561.00 Reduced
General-duty citation text
29 CFR 1926.451(c)(2)(i): Footings were not level, sound, rigid and capable of supporting the loaded scaffold without settling or displacement: On or about 4/18/2025, at the jobsite located at 101 Dory Rd, North Palm Beach, FL 33408, employees were exposed to a 6.7-foot fall hazard while working from a scaffold which was stabilized by placing a wood piece under a leg of an end frame.
Recent events (2)
- — I (S) $1560.5
- — Z (S) $3121
1926.452 C02
- Issued
- Penalty
- Initial $3121.00 · Current $1561.00 Reduced
General-duty citation text
29 CFR 1926.452(c)(2): Tubular welded frames and panels were not braced by cross, horizontal, or diagonal braces, or combination thereof, which would have secured vertical members together laterally: On or about 4/18/2025, at the jobsite located at 101 Dory Rd, North Palm Beach, FL 33408, employees were exposed to a 6.7-foot fall hazard while working from a scaffold that lacked a cross brace.
Recent events (2)
- — I (S) $1560.5
- — Z (S) $3121
More inspections at CRE CONSTRUCTION LLC
NORTH PALM BEACH, FL—2024-03-04 00:00:00
CRE CONSTRUCTION LLC
View CRE CONSTRUCTION LLC's full OSHA safety record →
More inspections in this industry (NAICS 236118)
CORTLANDT MANOR, NY—2026-07-13
RJW RENOVATIONS, LLC
VANCOUVER, WA—2026-07-08
WA317991978 - DLS CONTRACTING INC
NEWPORT BEACH, CA—2026-07-08
DRAKE SMITH CONSTRUCTION
BRIDGEVILLE, PA—2026-07-08
EXTREME DECKS
COLUMBUS, OH—2026-07-07
QUALITY BUILDS OHIO LLC
More inspections in FL
MARIANNA, FL—2026-07-13
PRIMETIME MOBILE MASONRY LLC
MELBOURNE, FL—2026-07-13
OMNIPOTENT BRANDS, LLC
QUINCY, FL—2026-07-13
WALMART
INDIAN ROCKS BEACH, FL—2026-07-10
UNKNOWN CONTRACTOR
CLEARWATER, FL—2026-07-10
ROOFTECH ROOFING & WATERPROOFING INC
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 348191503.