ORLANDO, FL —
OSHA Inspection: KEIDSER SERVICE, INC.
Complaint inspection · Health discipline
At a glance
On , OSHA opened a complaint health inspection of KEIDSER SERVICE, INC. in 4040 CENTRAL FLORIDA PARKWAY, ORLANDO, FL 32837 (NAICS 561790). OSHA activity number 348214065.
Where did this inspection happen?
- Establishment
- KEIDSER SERVICE, INC.
- Site address
- 4040 CENTRAL FLORIDA PARKWAY
- City
- ORLANDO
- State
- FL
- ZIP
- 32837
- Mailing
- 8256 EXCHANGE DRIVE, UNIT 234 #234, ORLANDO, FL 32809
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 561790
- Employees
- 23
- Ownership type
- A
Citations
2 citations on file for this inspection.
1910.134 E01
- Issued
- Penalty
- Initial $2894.00 · Current $2894.00
1430
General-duty citation text
29 CFR 1910.134(e)(1): The employer did not provide a medical evaluation to determine the employee's ability to use a respirator, before the employee was fit tested or required to use the respirator in the workplace: a. On or about April 24, 2025, at the job site: employees working with chloride and muriatic acid were exposed to respiratory hazards in that the employer did not ensure that employees using 3M 6200 half face elastomeric respirators received a medical evaluation prior to initial use of the respirator.
Recent events (1)
- — Z (S) $2894
1910.134 F02
- Issued
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.134(f)(2): Employee(s) using tight-fitting facepiece respirators were not fit tested prior to initial use of the respirator: a. On or about April 24, 2025, at the job site: employees working with chloride and muriatic acid were exposed to respiratory hazards in that the employer did not ensure that employees using 3M 6200 half face elastomeric respirators were fit tested prior to initial use of the respirator
Recent events (1)
- — Z (S) $0
More inspections in this industry (NAICS 561790)
EAU CLAIRE, WI—2026-07-10
MIDWEST POWER WASHING, LLC
TUCSON, AZ—2026-07-08
CPX2026XSS813X0009 - SKYTEK BUILDING SERVICES, L.L.C.
ROANOKE, VA—2026-07-07
UNDER ONE ROOF HOME LIQUIDATION AND ESTATE SERVICES, INC.
BREMERTON, WA—2026-07-02
WA317991921 - KITSAP POWER WASH LLC
EVERETT, WA—2026-07-01
WA317991922 - NATIONAL FACILITY CONTRACTORS LLC
More inspections in FL
MARIANNA, FL—2026-07-16
BRANNON BROTHERS CONSTRUCTION, LLC
LAKELAND, FL—2026-07-16
SOUTHERN MILLING & LUMBER, INC.
OAKLAND PARK, FL—2026-07-16
PKB CABINETRY
LAKELAND, FL—2026-07-16
ELIJAH WHOLESALE, LLC.
TAMPA, FL—2026-07-16
VALENCIA WHOLESALE, INC.
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 348214065.