Safety Incidents OSHA Severe Injury Reports · 2015–2025
2,004,209Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: FONTES FRAMING

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of FONTES FRAMING in 4503-4507 TENNYSON STREET, DENVER, CO 80212 (NAICS 238130). OSHA activity number 348245622.

Watch Fontes Framing — free Get an email when a new federal OSHA severe-injury report for Fontes Framing is published. One employer, no account, unsubscribe in one click.
Establishment
FONTES FRAMING
Site address
4503-4507 TENNYSON STREET
City
DENVER
State
CO
ZIP
80212
Mailing
1316 E. 101ST AVENUE, THORNTON, CO 80229
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238130
Employees
3
Ownership type
A

1 citation on file for this inspection.

1926.501 B13

Serious Gravity 5 1 instance 2 exposed
Issued
Penalty
Initial $3015.00 · Current $3015.00
29 CFR  1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b):   (a)  On or before May 14, 2025, the employer did not ensure that employees framing on the unfinished second story of a three-story apartment building were utilizing a fall protection system when working at and near the edge.  This condition exposed the employees to a fall of approximately 21 feet to the ground below.