On , OSHA opened a planned safety inspection of JHC RESIDENTIAL AND COMMERCIAL SERVICES LLC in 1003 WEST INDIANTOWN ROAD, JUPITER, FL 33458 (NAICS 238160). OSHA activity number 348282302.

Watch JHC Residential AND Commercial Services LLC — free Get an email when a new federal OSHA severe-injury report for JHC Residential AND Commercial Services LLC is published. One employer, no account, unsubscribe in one click.
Site address
1003 WEST INDIANTOWN ROAD
City
JUPITER
State
FL
ZIP
33458
Mailing
2600 HIGH RIDGE ROAD, BOYNTON BEACH, FL 33426
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Last modified
Data loaded
NAICS code
238160
Employees
25
Ownership type
A

2 citations on file for this inspection.

1926.501 B10

Serious Gravity 5 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $3405.00 · Current $1703.00 Reduced
29 CFR  1926.501(b)(10): Each employee engaged in roofing activities on low-slope roofs with unprotected sides and edges 6 feet or more above lower levels, was not protected from falling by guardrail systems, safety net systems, personal fall arrest systems, or a combination of warning line system and guardrail system, warning line system and safety net system, or warning line system and personal fall arrest system, or warning line system and safety monitoring system.  Or, on roofs 50-feet (15.25 m) or less in width, each employee was not protected by use of a monitoring system:  On or about 06/02/2025, at 1003 West Indian Town Road, Jupiter, Florida, employees repairing roofing work were exposed to a fall hazard of approximately 12.5 feet, while not being protected from falling to the lower level.
Recent events (2)
  • — I (S) $1703
  • — Z (S) $3405

1926.1053 B01

Serious Gravity 5 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $2270.00 · Current $1135.00 Reduced
29 CFR 1926.1053(b)(1): Where portable ladders were used for access to an upper landing surface and the ladder's length allows, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface being accessed:  On or about 02-05-2025, at 1003 Indiantown Road, Jupiter, Florida, employees engaged in roofing activities (repair work)were exposed to a 12.5-foot fall hazard while using a ladder not extended at least 3 feet beyond the upper landing surface and was not secured at the top.