HAZLETON, PA —
OSHA Inspection: DTL CONSTRUCTION LLC
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of DTL CONSTRUCTION LLC in 33 S POPLAR ST, HAZLETON, PA 18201 (NAICS 238160). OSHA activity number 348291311.
Where did this inspection happen?
- Establishment
- DTL CONSTRUCTION LLC
- Site address
- 33 S POPLAR ST
- City
- HAZLETON
- State
- PA
- ZIP
- 18201
- Mailing
- 409 E DIAMOND AVE, HAZLETON, PA 18201
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238160
- Employees
- 6
- Ownership type
- A
Citations
4 citations on file for this inspection.
1903.19 C01
- Issued
- Abate by
- Penalty
- Initial $398.00 · Current $398.00
General-duty citation text
29 CFR 1903.19(c)(1):The employer did not certify to OSHA, within 10 calendar days after the abatement date, that the cited violation had been abated: a) Back Roof - On or about June 23 2025, the employer did not provide a written certification to OSHA that the abatement was complete.
Recent events (1)
- — Z (O) $398
1926.501 B13
- Issued
- Abate by
- Penalty
- Initial $3547.00 · Current $2547.00 Reduced
General-duty citation text
29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): a) Back Roof - On or about June 4, 2024, an employees receiving chimney bricks was not protected from falling approximately 19 feet with a guardrail system, safety net system or personal fall arrest system. ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
- — I (S) $2547
- — Z (S) $3547
1926.502 D17
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1926.502(d)(17):The attachment point of the body harness was not located in the center of the wearer's back near shoulder level, or above the wearer's head: a) Rear Roof - On or about June 4, 2025, an employee was exposed to a fall hazard of approximately nineteen (19) feet without the D-Link attached to the center of their back. ABATEMENT CERTIFICATION AND DOCUMENTATION REQUIRED
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.552 A01
- Issued
- Abate by
- Penalty
- Initial $4965.00 · Current $2985.00 Reduced
General-duty citation text
29 CFR 1926.552(a)(1): The employer did not comply with the manufacturer's specifications and limitations applicable to the operation of all hoists and elevators: a) Right Side of House - On or about June 4, 2025, employees were exposed to fall hazards while using a material hoist as a ladder which violated the manufacturer's specifications. ABATEMENT CERTIFICATION AND DOCUMENTATION REQUIRED
Recent events (2)
- — I (S) $2985
- — Z (S) $4965
More inspections in this industry (NAICS 238160)
SIOUX FALLS, SD—2026-07-13
H & R ROOFING OF SOUTH DAKOTA, INC.
HENDERSON, NV—2026-07-13
INTEGRITY ROOFING LLC
CORTLANDT MANOR, NY—2026-07-13
LG BUILDERS INC.
CAMDEN, OH—2026-07-13
ALBERTO MORALES
BLOOMINGTON, IL—2026-07-13
UNKNOWN CONTRACTOR
More inspections in PA
MILTON, PA—2026-07-10
HOMETOWN FOODS CHEF BOYARDEE CO.
SUNBURY, PA—2026-07-10
DEMPSEY UNIFORM & LINEN SUPPLY, INC
LANDISVILLE, PA—2026-07-10
FAIRVIEW DEMOLITION LLC
YORK, PA—2026-07-10
AMERICAN SPECIALTY SYSTEMS INC.
WILLIAMSPORT, PA—2026-07-10
INTERNATIONAL PAINT PROS
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 348291311.