Safety Incidents OSHA Severe Injury Reports · 2015–2025
2,004,209Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: DTL CONSTRUCTION LLC

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of DTL CONSTRUCTION LLC in 33 S POPLAR ST, HAZLETON, PA 18201 (NAICS 238160). OSHA activity number 348291311.

Watch DTL Construction LLC — free Get an email when a new federal OSHA severe-injury report for DTL Construction LLC is published. One employer, no account, unsubscribe in one click.
Site address
33 S POPLAR ST
City
HAZLETON
State
PA
ZIP
18201
Mailing
409 E DIAMOND AVE, HAZLETON, PA 18201
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Last modified
Data loaded
NAICS code
238160
Employees
6
Ownership type
A

4 citations on file for this inspection.

1903.19 C01

Other-than-serious 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $398.00 · Current $398.00
29 CFR  1903.19(c)(1):The employer did not certify to OSHA, within 10 calendar days after the abatement date, that the cited violation had been abated:  a) Back Roof - On or about June 23 2025, the employer did not provide a written certification to OSHA that the abatement was complete.
Recent events (1)
  • — Z (O) $398

1926.501 B13

Serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $3547.00 · Current $2547.00 Reduced
29 CFR  1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b):  a) Back Roof - On or about June 4, 2024, an employees receiving chimney bricks was not protected from falling approximately 19 feet with a guardrail system, safety net system or personal fall arrest system.  ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
  • — I (S) $2547
  • — Z (S) $3547

1926.502 D17

Serious Gravity 10 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR  1926.502(d)(17):The attachment point of the body harness was not located in the center of the wearer's back near shoulder level, or above the wearer's head:  a) Rear Roof - On or about June 4, 2025, an employee was exposed to a fall hazard of approximately nineteen (19) feet without the D-Link attached to the center of their back.  ABATEMENT CERTIFICATION AND DOCUMENTATION REQUIRED
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.552 A01

Serious Gravity 10 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $4965.00 · Current $2985.00 Reduced
29 CFR 1926.552(a)(1): The employer did not comply with the manufacturer's specifications and limitations applicable to the operation of all hoists and elevators:  a) Right Side of House - On or about June 4, 2025, employees were exposed to fall hazards while using a material hoist as a ladder which violated the manufacturer's specifications.  ABATEMENT CERTIFICATION AND DOCUMENTATION REQUIRED
Recent events (2)
  • — I (S) $2985
  • — Z (S) $4965

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 348291311.