Safety Incidents OSHA Severe Injury Reports · 2015–2025
4,113,118Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: DON NICO'S ROOFING, LLC

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of DON NICO'S ROOFING, LLC in 3541 WINDWARD LANE, APPLETON, WI 54911 (NAICS 238160). OSHA activity number 348304510.

Watch DON Nico'S Roofing, LLC — free Get an email when a new federal OSHA severe-injury report for DON Nico'S Roofing, LLC is published. One employer, no account, unsubscribe in one click.
Site address
3541 WINDWARD LANE
City
APPLETON
State
WI
ZIP
54911
Mailing
904 PLANK ROAD, MENASHA, WI 54952
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238160
Employees
6
Ownership type
A

4 citations on file for this inspection.

1926.20 B02

Serious Gravity 1 1 instance 6 exposed
Issued
Penalty
Initial $2128.00 · Current $2128.00
29 CFR 1926.20(b)(2): Such programs shall provide for frequent and regular inspections of the job sites, materials, and equipment to be made by competent persons designated by the employers.  On or about June 11, 2024, at a worksite located at 3541 Windward Lane, Appleton, Wisconsin, a representative of the employer was onsite and did not ensure that frequent and regular inspections of the job site, material and equipment had been completed to ensure that employees performing roofing activities were protected from falls.
Recent events (1)
  • — Z (S) $2128

1926.501 B13

Serious Gravity 1 1 instance 6 exposed
Issued
Penalty
Initial $2128.00 · Current $2128.00
29 CFR 1926.501(b)(13): Residential construction. Each employee engaged in residential construction activities 6 feet (1.8 m) or more above lower levels shall be protected by guardrail systems, safety net system, or personal fall arrest system unless another provision in paragraph (b) of this section provides for an alternative fall protection measure. Exception: When the employer can demonstrate that it is infeasible or creates a greater hazard to use these systems, the employer shall develop and implement a fall protection plan which meets the requirements of paragraph (k) of � 1926.502.  Note: There is a presumption that it is feasible and will not create a greater hazard to implement at least one of the above-listed fall protection systems. Accordingly, the employer has the burden of establishing that it is appropriate to implement a fall protection plan which complies with � 1926.502(k) for a particular workplace situation, in lieu of implementing any of those systems.  On or about June 11, 2025, at a worksite located at 3541 Windward Lane, Appleton, Wisconsin, employees were exposed to fall hazards of 8 feet, 9 inches while removing shingles on a residential construction site without the use of conventional fall protection.
Recent events (1)
  • — Z (S) $2128

1926.1053 B01

Serious Gravity 1 1 instance 6 exposed
Issued
Penalty
Initial $2128.00 · Current $2128.00
29 CFR  1926.1053(b)(1):When portable ladders are used for access to an upper landing surface, the ladder side rails shall extend at least 3 feet (.9 m) above the upper landing surface to which the ladder is used to gain access; or, when such an extension is not possible because of the ladder's length, then the ladder shall be secured at its top to a rigid support that will not deflect, and a grasping device, such as a grabrail, shall be provided to assist employees in mounting and dismounting the ladder. In no case shall the extension be such that ladder deflection under a load would, by itself, cause the ladder to slip off its support.  On or about June 11, 2025, at a worksite located at 3541 Windward Lane, Appleton, Wisconsin, employees were exposed to fall hazard of 8 feet, 9 inches feet while using a Keller Type II ladder to access and egress an upper landing surface when the mobile ladder was not extended 3 feet above the landing surface nor was it secured and a grasping device provided.
Recent events (1)
  • — Z (S) $2128

1926.1053 B05 I

Serious Gravity 1 1 instance 6 exposed
Issued
Penalty
Initial $0.00 · Current $0.00
1926.1053(b)(5)(i): Non-self-supporting ladders shall be used at an angle such that the horizontal distance from the top support to the foot of the ladder is approximately one-quarter of the working length of the ladder (the distance along the ladder between the foot and the top support).  On or about June 11, 2025, at a worksite located at 3541 Windward Lane, Appleton, Wisconsin, employees were exposed to fall hazard of 8 feet, 9 inches feet while using a Keller Type II ladder which was positioned at an angle of 61.6 degrees exposing employees to slip and fall hazards.
Recent events (1)
  • — Z (S) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 348304510.