OSHA Inspection: WELLSFORD CABINETRY INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of WELLSFORD CABINETRY INC. in 1810 WEST HIGH STREET, POTTSTOWN, PA 19464 (NAICS 337110). OSHA activity number 348313040.

Watch Wellsford Cabinetry INC. — free Get an email when a new federal OSHA severe-injury report for Wellsford Cabinetry INC. is published. One employer, no account, unsubscribe in one click.
Site address
1810 WEST HIGH STREET
City
POTTSTOWN
State
PA
ZIP
19464
Mailing
1810 WEST HIGH STREET, POTTSTOWN, PA 19464
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
337110
Employees
26
Ownership type
A

4 citations on file for this inspection.

1910.212 A01

Serious Gravity 1 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $3376.00 · Current $1520.00 Reduced
29 CFR  1910.212(a)(1):One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks:  (a)  1810 West High Street, Pottstown, PA 19464, shop floor: On or about June 16, 2025 - employees used Delta drill press where the chuck  was unguarded at the point of operation, exposing the operator/employee to an entanglement hazard.
Recent events (3)
  • — F (S) $1519.5
  • — C (S) $3376
  • — Z (S) $3376

1910.213 C01

Serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $6753.00 · Current $3546.00 Reduced
29 CFR  1910.213(c)(1): Each circular hand-fed ripsaw was not guarded by a hood which completely enclosed that portion of the saw above the table and that portion of the saw above the material being cut:  (a) 11810 West High Street, Pottstown, PA 19464, shop floor: On or about June 16, 2025 - employees used Saw Stop table saws where the saw blade  was unguarded at the point of operation, exposing the operator/employee to an amputation hazard.  (b) 11810 West High Street, Pottstown, PA 19464, shop floor: On or about June 16, 2025 - employees used Powermatic table saw where the saw blade  was unguarded at the point of operation, exposing the operator/employee to an amputation hazard.  (c) 1810 West High Street, Pottstown, PA 19464, shop floor: On or about June 16, 2025 - employees used a Delta Rockwell table saw where the saw blade  was unguarded at the point of operation, exposing the operator/employee to an amputation hazard.  (d) 1810 West High Street, Pottstown, PA 19464, shop floor: On or about June 16, 2025 - employees used Jet table saw where the saw blade  was unguarded at the point of operation, exposing the operator/employee to an amputation hazard.
Recent events (3)
  • — F (S) $3545.5
  • — C (S) $6753
  • — Z (S) $6753

1910.213 P04

Serious Gravity 1 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR  1910.213(p)(4): Belt sanding machinery was not provided with a guard at each nip point where the sanding belt ran onto a pulley, to prevent the operator's hands or fingers from coming into contact with nip points:   (a)1810 West High Street, Pottstown, PA 19464, shop floor: On or about June 16, 2025 - employees used a Crouch Oscillating Edge Sander lacking adequate methods of machine guarding at the belt pulleys which exposed them to ingoing nip points and rotating parts.
Recent events (3)
  • — F (S) $0
  • — C (S) $0
  • — Z (S) $0

1910.303 G01

Other-than-serious 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR  1910.303(g)(1):Sufficient access and working space was not provided and maintained about all electric equipment (operating at 600 volts, nominal, or less to ground) to permit ready and safe operation and maintenance of such equipment:  a) 1810 West High Street, Pottstown, PA 19464, shop floor: On or about June 16, 2025 - sufficient access to the electrical panels was not readily available to permit safe operation and maintenance of the equipment.