POTTSTOWN, PA —
OSHA Inspection: WELLSFORD CABINETRY INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of WELLSFORD CABINETRY INC. in 1810 WEST HIGH STREET, POTTSTOWN, PA 19464 (NAICS 337110). OSHA activity number 348313040.
Where did this inspection happen?
- Establishment
- WELLSFORD CABINETRY INC.
- Site address
- 1810 WEST HIGH STREET
- City
- POTTSTOWN
- State
- PA
- ZIP
- 19464
- Mailing
- 1810 WEST HIGH STREET, POTTSTOWN, PA 19464
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 337110
- Employees
- 26
- Ownership type
- A
Citations
4 citations on file for this inspection.
1910.212 A01
- Issued
- Abate by
- Penalty
- Initial $3376.00 · Current $1520.00 Reduced
General-duty citation text
29 CFR 1910.212(a)(1):One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks: (a) 1810 West High Street, Pottstown, PA 19464, shop floor: On or about June 16, 2025 - employees used Delta drill press where the chuck was unguarded at the point of operation, exposing the operator/employee to an entanglement hazard.
Recent events (3)
- — F (S) $1519.5
- — C (S) $3376
- — Z (S) $3376
1910.213 C01
- Issued
- Abate by
- Penalty
- Initial $6753.00 · Current $3546.00 Reduced
General-duty citation text
29 CFR 1910.213(c)(1): Each circular hand-fed ripsaw was not guarded by a hood which completely enclosed that portion of the saw above the table and that portion of the saw above the material being cut: (a) 11810 West High Street, Pottstown, PA 19464, shop floor: On or about June 16, 2025 - employees used Saw Stop table saws where the saw blade was unguarded at the point of operation, exposing the operator/employee to an amputation hazard. (b) 11810 West High Street, Pottstown, PA 19464, shop floor: On or about June 16, 2025 - employees used Powermatic table saw where the saw blade was unguarded at the point of operation, exposing the operator/employee to an amputation hazard. (c) 1810 West High Street, Pottstown, PA 19464, shop floor: On or about June 16, 2025 - employees used a Delta Rockwell table saw where the saw blade was unguarded at the point of operation, exposing the operator/employee to an amputation hazard. (d) 1810 West High Street, Pottstown, PA 19464, shop floor: On or about June 16, 2025 - employees used Jet table saw where the saw blade was unguarded at the point of operation, exposing the operator/employee to an amputation hazard.
Recent events (3)
- — F (S) $3545.5
- — C (S) $6753
- — Z (S) $6753
1910.213 P04
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.213(p)(4): Belt sanding machinery was not provided with a guard at each nip point where the sanding belt ran onto a pulley, to prevent the operator's hands or fingers from coming into contact with nip points: (a)1810 West High Street, Pottstown, PA 19464, shop floor: On or about June 16, 2025 - employees used a Crouch Oscillating Edge Sander lacking adequate methods of machine guarding at the belt pulleys which exposed them to ingoing nip points and rotating parts.
Recent events (3)
- — F (S) $0
- — C (S) $0
- — Z (S) $0
1910.303 G01
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.303(g)(1):Sufficient access and working space was not provided and maintained about all electric equipment (operating at 600 volts, nominal, or less to ground) to permit ready and safe operation and maintenance of such equipment: a) 1810 West High Street, Pottstown, PA 19464, shop floor: On or about June 16, 2025 - sufficient access to the electrical panels was not readily available to permit safe operation and maintenance of the equipment.
Recent events (3)
- — F (O) $0
- — C (O) $0
- — Z (O) $0
More inspections in this industry (NAICS 337110)
OAKLAND PARK, FL—2026-07-16
PKB CABINETRY
ORLANDO, FL—2026-07-15
ROSTOV, LLC
RICHMOND HILL, GA—2026-07-14
WILSON CABINETRY, LLC
VESTAL, NY—2026-07-08
BARNWOOD KITCHEN CABINETS
DEERWOOD, MN—2026-07-02
111522 - DUFFNEY CUSTOM CABINETS LLC
More inspections in PA
PHILADELPHIA, PA—2026-07-16
URUS CONSTRUCTION CORPORATION
JEFFERSON HILLS, PA—2026-07-16
MARATHON PETROLEUM COMPANY ASPHALT TERMINAL
SMITHFIELD, PA—2026-07-16
CARLISLE CONSTRUCTION MATERIALS
PITTSBURGH, PA—2026-07-15
DREAM GREENER LAWN & LANDSCAPE
COCHRANTON, PA—2026-07-15
CRAWFORD COUNTY HARDWOODS, LLC
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 348313040.