OSHA Inspection: MCQUILLEN CHEVROLET GMC, INC.

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of MCQUILLEN CHEVROLET GMC, INC. in 604 MAIN STREET EAST, GIRARD, PA 16417 (NAICS 811111). OSHA activity number 348319864.

Watch Mcquillen Chevrolet GMC, INC. — free Get an email when a new federal OSHA severe-injury report for Mcquillen Chevrolet GMC, INC. is published. One employer, no account, unsubscribe in one click.
Site address
604 MAIN STREET EAST
City
GIRARD
State
PA
ZIP
16417
Mailing
604 MAIN STREET EAST, GIRARD, PA 16417
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Last modified
Data loaded
NAICS code
811111
Employees
22
Ownership type
A

9 citations on file for this inspection.

1910.157 C01

Serious Gravity 5 2 instances 10 exposed
Issued
Abate by
Penalty
Initial $2837.00 · Current $1250.00 Reduced
29 CFR  1910.157(c)(1):Portable fire extinguishers were not mounted, located and identified so that they were readily accessible without subjecting the employees to injuries:  a.)  McQuillen Chevrolet GMC, Inc.1st garage by north door  -  On or about  6/18/25, and at times prior thereto, an ABC fire extinguisher was sitting on the floor by a garage door instead of being mounted.  b.) McQuillen Chevrolet GMC, Inc. , 1st garage by ramp to office -  On or about 6/18/25, and at times prior thereto, an ABC fire extinguisher was blocked by boxes stored in front of it.  ABATEMENT CERTIFICATION REQUIRED: Abatement certification is required within 10 days after the abatement date noted on the citation (see below).  This certification shall include a statement that abatement is complete, the date abatement was completed, method of abatement, and state that employees and their representatives were informed of this abatement.
Recent events (2)
  • — I (S) $1250
  • — Z (S) $2837

1910.157 E01

Serious Gravity 5 1 instance 10 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR  1910.157(e)(1):The employer shall be responsible for the inspection, maintenance and testing of all portable fire extinguishers in the workplace:  a.)  McQuillen Chevrolet GMC, Inc. - On or about 6/18/25 and at times prior thereto, monthly visual inspections were not conducted on the  ABC fire extinguishers throughout the service center and garages.    ABATEMENT CERTIFICATION REQUIRED: Abatement certification is required within 10 days after the abatement date noted on the citation (see below).  This certification shall include a statement that abatement is complete, the date abatement was completed, method of abatement, and state that employees and their representatives were informed of this abatement.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.215 A04

Serious Gravity 5 1 instance 10 exposed
Issued
Abate by
Penalty
Initial $2837.00 · Current $1250.00 Reduced
29 CFR  1910.215(a)(4): Work rest(s) on grinding machinery were not adjusted closely to the wheel with a maximum opening of one eighth inch:  a.) McQuillen Chevrolet GMC, Inc. garage bay - on or about 6/18/25 and times prior thereto: The work rest for the grinding wheel on the 6" Black and Decker bench grinder (#8627) was positioned 7/8 inch away from the work rest.  ABATEMENT CERTIFICATION REQUIRED: Abatement certification is required within 10 days after the abatement date noted on the citation (see below).  This certification shall include a statement that abatement is complete, the date abatement was completed, method of abatement, and state that employees and their representatives were informed of this abatement.
Recent events (2)
  • — I (S) $1250
  • — Z (S) $2837

1910.215 B09

Serious Gravity 5 1 instance 10 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR  1910.215(b)(9): The distance between the abrasive wheel periphery(s) and the adjustable tongue or the end of the safety guard peripheral member at the top exceeded one fourth inch:  a.) McQuillen Chevrolet GMC, Inc. garage bay - on or about 6/18/25 and times prior thereto: The tongue guard for the grinding wheel on the 6" Black and Decker bench grinder (#8627) was positioned 1 inch away from the grinding wheel.  ABATEMENT CERTIFICATION REQUIRED: Abatement certification is required within 10 days after the abatement date noted on the citation (see below).  This certification shall include a statement that abatement is complete, the date abatement was completed, method of abatement, and state that employees and their representatives were informed of this abatement.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.303 B02

Serious Gravity 5 1 instance 10 exposed
Issued
Abate by
Penalty
Initial $2837.00 · Current $1250.00 Reduced
29 CFR  1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling:  a.)  McQuillen Chevrolet GMC, Inc.; east side of 1st service center garage on pole by 2nd to last bay  - On or about  6/18/25, and at times prior thereto,  an electrical outlet had damage.  The bottom was missing the covering for the outlet area where the cord is plugged in.    ABATEMENT CERTIFICATION REQUIRED: Abatement certification is required within 10 days after the abatement date noted on the citation (see below).  This certification shall include a statement that abatement is complete, the date abatement was completed, method of abatement, and state that employees and their representatives were informed of this abatement.
Recent events (2)
  • — I (S) $1250
  • — Z (S) $2837

1910.303 G01 II

Serious Gravity 1 1 instance 10 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR  1910.303(g)(1)(ii):The required working space about electric equipment rated 600 volts, nominal, or less to ground, was used for storage:  a.)  McQuillen Chevrolet GMC, Inc.,  garage, near service center door -  On or about 6/18/25, and at times prior thereto, the area in front of an electrical panel box was used for storage.  Items stored in front of the panel box, included, but were not limited to, cardboard boxes, plastic tote, and air compressor.  ABATEMENT CERTIFICATION REQUIRED: Abatement certification is required within 10 days after the abatement date noted on the citation (see below).  This certification shall include a statement that abatement is complete, the date abatement was completed, method of abatement, and state that employees and their representatives were informed of this abatement.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.1200 E01

Serious Gravity 1 1 instance 10 exposed
Issued
Abate by
Penalty
Initial $2128.00 · Current $1250.00 Reduced
29 CFR  1910.1200(e)(1): Employer had not developed or implemented a written hazard communication program that included the requirements outlined in 29 CFR 1910.1200(e)(1)(i) and (e)(1)(ii):   a.)  McQuillen Chevrolet GMC, Inc., service center garage - On or about 6/18/25, and at times prior thereto, the company had not developed and implemented a written hazard communication program.  Employees worked with and around chemicals including, but not limited to, gasoline, diesel, oil,  and parts cleaner.  ABATEMENT CERTIFICATION REQUIRED: Abatement certification is required within 10 days after the abatement date noted on the citation (see below).  This certification shall include a statement that abatement is complete, the date abatement was completed, method of abatement, and state that employees and their representatives were informed of this abatement
Recent events (2)
  • — I (S) $1250
  • — Z (S) $2128

1910.1200 F06 II

Serious Gravity 1 1 instance 5 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00

Hazardous substances P108

29 CFR  1910.1200(f)(6)(ii): Except as provided in 29 CFR 1910.1200(f)(7) and 29 CFR 1910.1200(f)(8), the employer did not ensure that each container of hazardous chemicals in the workplace was labeled, tagged or marked with the product identifier and words, pictures, symbols, or combination thereof, which provide at least general information regarding the hazards of the chemicals and which, in conjunction with the other information immediately available to employees under the hazard communication program, would provide employees with the specific information regarding the physical and health hazards of the hazardous chemical:  a)  McQuillen Chevrolet GMS, Inc.  2nd service garage, on middle table - on or about 6/18/25, and times prior thereto:  Secondary containers of products including, but not limited to, oil and transmission fluid was not labeled with a product identifier nor the hazards of the hazardous chemical(s) container therein.   ABATEMENT CERTIFICATION REQUIRED: Abatement certification is required within 10 days after the abatement date noted on the citation (see below).  This certification shall include a statement that abatement is complete, the date abatement was completed, method of abatement, and state that employees and their representatives were informed of this abatement.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.145 E02

Other-than-serious 2 instances 10 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR  1910.145(e)(2):The wording of signs was not easily read and concise.  a.)  McQuillen Chevrolet GMC, Inc., east side of 1st service center garage on pole by 2nd to last bay  - On or about 6/18/25, and at times prior thereto, caution signage was illegible due to the sign being torn and missing pieces.  b.)  McQuillen Chevrolet GMC, Inc., east side of 1st service center garage on pole by 2nd to last bay  - On or about 6/18/25, and at times prior thereto, warning signage was illegible due to the sign being torn and missing pieces.  ABATEMENT CERTIFICATION REQUIRED: Abatement certification is required within 10 days after the abatement date noted on the citation (see below).  This certification shall include a statement that abatement is complete, the date abatement was completed, method of abatement, and state that employees and their representatives were informed of this abatement.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 348319864.