ASTORIA, NY —
OSHA Inspection: ELECTROTECH SERVICE EQUIPMENT CORP
Complaint inspection · Health discipline
At a glance
On , OSHA opened a complaint health inspection of ELECTROTECH SERVICE EQUIPMENT CORP in 24-50 46TH STREET, ASTORIA, NY 11103 (NAICS 335313). OSHA activity number 348320151.
Where did this inspection happen?
- Establishment
- ELECTROTECH SERVICE EQUIPMENT CORP
- Site address
- 24-50 46TH STREET
- City
- ASTORIA
- State
- NY
- ZIP
- 11103
- Mailing
- 24-50 46TH STREET, ASTORIA, NY 11103
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- A
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 335313
- Employees
- 57
- Ownership type
- A
Citations
6 citations on file for this inspection.
1910.1200 E01
- Issued
- Abate by
- Penalty
- Initial $4965.00 · Current $2482.00 Reduced
General-duty citation text
29 CFR 1910.1200(e)(1):The employer did not develop, implement, and/or maintain at the workplace a written hazard communication program which described how the criteria specified in 29 CFR 1910.1200(f), (g), and (h) would be met: Electrotech Service Equipment Corp. manufacturing facility 24-50 46th Street, Astoria, NY. a) Welding Department: Employees utilized hazardous materials such as toxic gases like argon, helium, welding wires and electrodes including Lincoln Electric Fleetweld 35, Radnor 4043, and SuperArc L-50 containing metallic oxides. The employer did not develop and implement a Hazard Communication Program; on or about 06/18/2025. Note: The employer is required to submit abatement certification for this item in accordance with 29 CFR 1903.19.
Recent events (2)
- — I (O) $2482
- — Z (S) $4965
1910.1200 G01
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.1200(g)(1): Employers did not have a safety data sheet in the workplace for each hazardous chemical which they use. Electrotech Service Equipment Corp.'s manufacturing facility 24-50 46th Street, Astoria, NY. a) Welding Department: Employees utilized hazardous materials such as toxic gases like argon, helium, welding wires and electrodes including Lincoln Electric Fleetweld 35, Radnor 4043, and SuperArc L-50 containing metallic oxides. Safety Data Sheets were not available for employee's review; on or about 06/18/2025. Note: The employer is required to submit abatement certification for this item in accordance with 29 CFR 1903.19
Recent events (2)
- — I (O) $0
- — Z (S) $0
1910.1200 H01
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.1200(h)(1): Employees were not provided effective information and training on hazardous chemicals in their work area at the time of their initial assignment and whenever a new hazard that the employees had not been previously trained about was introduced into their work area: Electrotech Service Equipment Corp.'s manufacturing facility 24-50 46th Street, Astoria, NY. a) Welding Department: Employees utilized hazardous materials such as toxic gases like argon, helium, welding wires and electrodes including Lincoln Electric Fleetweld 35, Radnor 4043, and SuperArc L-50 containing metallic oxides. A Hazard Communication Training Program was not place; on or about 06/18/2025. Note: The employer is required to submit abatement certification for this item in accordance with 29 CFR 1903.19
Recent events (2)
- — I (O) $0
- — Z (S) $0
1910.134 C02 I
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.134(c)(2)(i): Respirator users were not provided with the information contained in Appendix D to 29 CFR 1910.134 when the employer determined that any voluntary respirator use was permissible: Electrotech Service Equipment Corp.'s manufacturing facility 24-50 46th Street, Astoria, NY. Welding Department: Employees engaged in welding activities voluntarily used half face tight-fitting elastomeric respirators with gas/vapor cartridges/filters, P100. Information contained in Appendix D was not provided by the employer; on or about 06/18/2025. Note: The employer is required to submit abatement certification for this item in accordance with 29 CFR 1903.19
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.134 C02 II
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.134(c)(2)(ii): The employer did not establish and implement those elements of a written program necessary to ensure that any employee using a respirator voluntarily was medically able to use that respirator, and that the respirator was cleaned, stored, and maintained so that its use does not present a health hazard to the user: Electrotech Service Equipment Corp.'s manufacturing facility 24-50 46th Street, Astoria, NY. a) Welding Department: Employees engaged in welding activities voluntarily used half face elastomeric respirators. The employer did not develop and implement required elements of a written program for voluntary use of a respirator; on or about 06/18/2025. Note: The employer is required to submit abatement certification for this item in accordance with 29 CFR 1903.19
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.134 E01
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.134(e)(1):29 CFR 1910.134(e)(1): The employer did not provide a medical evaluation to determine the employee's ability to use a respirator, for voluntary use of the respirator in the workplace: Electrotech Service Equipment Corp.'s manufacturing facility 24-50 46th Street, Astoria, NY. a) Welding Department: Employees engaged in welding activities voluntarily used half faced tight-fitting elastomeric respirators with gas/vapor cartridges/filters, P100. The employer did not provide medical evaluations to the employee prior to voluntary use of respirators. Note: The employer is required to submit abatement certification for this item in accordance with 29 CFR 1903.19
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at ELECTROTECH SERVICE EQUIPMENT CORP
ASTORIA, NY—2018-06-11 00:00:00
ELECTROTECH SERVICE EQUIPMENT CORP
View ELECTROTECH SERVICE EQUIPMENT CORP's full OSHA safety record →
More inspections in this industry (NAICS 335313)
POLK, PA—2026-06-25
VOYTEN ELECTRIC AND ELECTRONICS, INC.
REMLAP, AL—2026-05-28
SOUTHEASTERN MANUFACTURING INC
BEAVER, PA—2026-03-04
EATON CORPORATION
BEAVER, PA—2026-03-04
EATON CORPORATION
COVERT, MI—2026-02-09
SIEMENS ENERGY, INC.
More inspections in NY
POUGHKEEPSIE, NY—2026-07-13
MARCO BOARD HOUSE, INC.
CORTLANDT MANOR, NY—2026-07-13
LG BUILDERS INC.
CORTLANDT MANOR, NY—2026-07-13
RJW RENOVATIONS, LLC
HEMPSTEAD, NY—2026-07-13
NYSDOCCS NASSAU AREA OFFICE
NIAGARA FALLS, NY—2026-07-10
NTVI FEDERAL INC
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 348320151.